enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Heisler chart - Wikipedia

    en.wikipedia.org/wiki/Heisler_Chart

    These first Heisler–Gröber charts were based upon the first term of the exact Fourier series solution for an infinite plane wall: (,) = = [⁡ + ⁡ ⁡], [1]where T i is the initial uniform temperature of the slab, T ∞ is the constant environmental temperature imposed at the boundary, x is the location in the plane wall, λ is the root of λ * tan λ = Bi, and α is thermal diffusivity.

  3. Cooling curve - Wikipedia

    en.wikipedia.org/wiki/Cooling_curve

    A cooling curve of naphthalene from liquid to solid. A cooling curve is a line graph that represents the change of phase of matter, typically from a gas to a solid or a liquid to a solid. The independent variable (X-axis) is time and the dependent variable (Y-axis) is temperature. [1] Below is an example of a cooling curve used in castings.

  4. Isothermal transformation diagram - Wikipedia

    en.wikipedia.org/wiki/Isothermal_transformation...

    However, greater undercooling by rapid quenching results in formation of martensite or bainite instead of pearlite. This is possible provided the cooling rate is such that the cooling curve intersects the martensite start temperature or the bainite start curve before intersecting the P s curve. The martensite transformation being a ...

  5. Thermodynamic diagrams - Wikipedia

    en.wikipedia.org/wiki/Thermodynamic_diagrams

    The main feature of thermodynamic diagrams is the equivalence between the area in the diagram and energy. When air changes pressure and temperature during a process and prescribes a closed curve within the diagram the area enclosed by this curve is proportional to the energy which has been gained or released by the air.

  6. Wet-bulb temperature - Wikipedia

    en.wikipedia.org/wiki/Wet-bulb_temperature

    The wet-bulb temperature is the lowest temperature that may be achieved by evaporative cooling of a water-wetted, ventilated surface.. By contrast, the dew point is the temperature to which the ambient air must be cooled to reach 100% relative humidity assuming there is no further evaporation into the air; it is the temperature where condensation (dew) and clouds would form.

  7. Continuous cooling transformation - Wikipedia

    en.wikipedia.org/wiki/Continuous_cooling...

    There are two types of continuous cooling diagrams drawn for practical purposes. Type 1: This is the plot beginning with the transformation start point, cooling with a specific transformation fraction and ending with a transformation finish temperature for all products against transformation time for each cooling curve.

  8. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    The coefficient of performance or COP (sometimes CP or CoP) of a heat pump, refrigerator or air conditioning system is a ratio of useful heating or cooling provided to work (energy) required. [1] [2] Higher COPs equate to higher efficiency, lower energy (power) consumption and thus lower operating costs. The COP is used in thermodynamics.

  9. Heat pump and refrigeration cycle - Wikipedia

    en.wikipedia.org/wiki/Heat_pump_and...

    Thermodynamic heat pump cycles or refrigeration cycles are the conceptual and mathematical models for heat pump, air conditioning and refrigeration systems. [1] A heat pump is a mechanical system that transmits heat from one location (the "source") at a certain temperature to another location (the "sink" or "heat sink") at a higher temperature. [2]