This diagram was created with another SVG tool. This SVG file contains embedded text that can be translated into your language, using any capable SVG editor, text editor or the SVG Translate tool . For more information see: About translating SVG files .
Most often, the other technique is some form of chromatography. Hyphenated techniques are widely used in chemistry and biochemistry. A slash is sometimes used instead of hyphen, especially if the name of one of the methods contains a hyphen itself. Examples of hyphenated techniques: Gas chromatography-mass spectrometry (GC-MS)
The design of the flame ionization detector varies from manufacturer to manufacturer, but the principles are the same. Most commonly, the FID is attached to a gas chromatography system. The eluent exits the gas chromatography column (A) and enters the FID detector’s oven (B). The oven is needed to make sure that as soon as the eluent exits ...
Gas chromatography (GC) is a common type of chromatography used in analytical chemistry for separating and analyzing compounds that can be vaporized without decomposition. Typical uses of GC include testing the purity of a particular substance, or separating the different components of a mixture. [ 1 ]
Electron capture detector developed by James Lovelock in the Science Museum, London Electron capture detector, Science History Institute. The electron capture detector is used for detecting electron-absorbing components (high electronegativity) such as halogenated compounds in the output stream of a gas chromatograph.
Diagram of the pressure instrumentation on a process vessel. Oil, gas and petrochemical processes are undertaken at specific operating pressures. Pressure is measured by pressure sensors (PE) which send pressure (PT) signals to pressure controllers (PIC). Pressure vessels and tanks are fitted with local pressure indicators (PI).
Many gas chromatograph detectors are ion detectors with varying methods of ionizing the components eluting from the gas chromatograph's column. [1] [2] An ion detector is analogous to a capacitor or vacuum tube. It can be envisioned as two metal grids separated by air with inverse charges placed on them.
The mass spectrometry process normally requires a very pure sample while gas chromatography using a traditional detector (e.g. Flame ionization detector) cannot differentiate between multiple molecules that happen to take the same amount of time to travel through the column (i.e. have the same retention time), which results in two or more ...