Search results
Results from the WOW.Com Content Network
Standard step method. The standard step method (STM) is a computational technique utilized to estimate one-dimensional surface water profiles in open channels with gradually varied flow under steady state conditions. It uses a combination of the energy, momentum, and continuity equations to determine water depth with a given a friction slope ...
Hygrometer. Dry / Wet-bulb temperature. v. t. e. Psychrometrics (or psychrometry, from Greek ψυχρόν (psuchron) 'cold' and μέτρον (metron) 'means of measurement'; [1][2] also called hygrometry) is the field of engineering concerned with the physical and thermodynamic properties of gas - vapor mixtures.
Streeter–Phelps equation. The Streeter–Phelps equation determines the relation between the dissolved oxygen concentration and the biological oxygen demand over time and is a solution to the linear first order differential equation [ 1 ] This differential equation states that the total change in oxygen deficit (D) is equal to the difference ...
Vincenty's formulae. Vincenty's formulae are two related iterative methods used in geodesy to calculate the distance between two points on the surface of a spheroid, developed by Thaddeus Vincenty (1975a). They are based on the assumption that the figure of the Earth is an oblate spheroid, and hence are more accurate than methods that assume a ...
Pressure as a function of the height above the sea level. There are two equations for computing pressure as a function of height. The first equation is applicable to the atmospheric layers in which the temperature is assumed to vary with altitude at a non null lapse rate of : = [,, ()] ′, The second equation is applicable to the atmospheric layers in which the temperature is assumed not to ...
This formula is accurate to within a degree or so when applied to the chirping of the field cricket. Counting can be sped up by simplifying the formula and counting the number of chirps produced in 15 seconds (N 15): = + Reformulated to give the temperature in degrees Celsius (°C), it is:
Since 1982, STP has been defined as a temperature of 273.15 K (0 °C, 32 °F) and an absolute pressure of exactly 10 5 Pa (100 kPa, 1 bar). NIST uses a temperature of 20 °C (293.15 K, 68 °F) and an absolute pressure of 1 atm (14.696 psi, 101.325 kPa). [ 3 ] This standard is also called normal temperature and pressure (abbreviated as NTP).
Cant (road and rail) Cant in a velodrome. The cant of a railway track or camber of a road (also referred to as superelevation, cross slope or cross fall) is the rate of change in elevation (height) between the two rails or edges of the road. This is normally greater where the railway or road is curved; raising the outer rail or the outer edge ...