Fire sprinkler application and installation guidelines, and overall fire sprinkler system design guidelines are provided by the National Fire Protection Association (NFPA) 13, (NFPA) 13D, and (NFPA) 13R and enforced by local jurisdictions.
A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used only in factories and large commercial buildings, systems for homes and small buildings are now available ...
The fire suppression piping may contain water, air (in a dry system), antifreeze, gas or chemicals as in a hood system, or a mixture producing fire retardant foam. Sprinkler fitters work with a variety of pipe and tubing materials including several types of plastic, copper, steel, cast iron, and ductile iron. [3]
External access point for fire sprinkler and dry standpipe at a building in San Francisco, US Antique wet standpipe preserved at Edison and Ford Winter Estates. A standpipe or riser is a type of rigid water piping which is built into multi-story buildings in a vertical position, or into bridges in a horizontal position, to which fire hoses can be connected, allowing manual application of water ...
The hydraulic calculation procedure is defined in the applicable reference model codes such as that published by the US-based National Fire Protection Association (NFPA), [2] or the EN 12845 standard, Fixed firefighting system – Automatic sprinkler systems – Design, installation and maintenance.
Fire alarm systems are required in most commercial buildings. They may include smoke detectors, heat detectors, and manual fire alarm activation devices (pull stations). All components of a fire alarm system are connected to a fire alarm control panel. Fire alarm control panels are usually found in an electrical or panel room.
The length of time required for a penetrant or sample on average to exceed a specified average heat rise above ambient at any single location determines the duration for the FT Rating (Fire and Temperature). If a hose-stream test is passed afterwards, the rating can then be expressed as an FTH Rating (Fire, Temperature and Hose-stream). The ...
In fire protection engineering, the K-factor formula is used to calculate the volumetric flow rate from a nozzle. Spray nozzles can for example be fire sprinklers or water mist nozzles, hose reel nozzles, water monitors and deluge fire system nozzles.