Search results

  1. Results from the WOW.Com Content Network
  2. Twist-on wire connector - Wikipedia

    en.wikipedia.org/wiki/Twist-on_wire_connector

    Twist-on wire connectors are not generally recommended for use with aluminum wire in the United States. [1] The U.S. Consumer Product Safety Commission disapproves wire nuts for aluminum wire; instead, special crimp connectors are called for, and as of 2011 the CPSC asserted qualified, second-preference approval of a certain kind of screw ...

  3. Aluminum building wiring - Wikipedia

    en.wikipedia.org/wiki/Aluminum_building_wiring

    Aluminum wire used before the mid-1970s had a somewhat higher rate of creep, but a more significant issue was that the same high price of copper driving the use of aluminum wire led to the use of brass-coated steel rather than solid brass screws for terminations at devices such as outlets and switches.

  4. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    The first rubber-insulated cables for US building wiring were introduced in 1922 with US patent 1458803, Burley, Harry & Rooney, Henry, "Insulated electric wire", issued 1923-06-12, assigned to Boston Insulated Wire and Cable . These were two or more solid copper electrical wires with rubber insulation, plus woven cotton cloth over each ...

  5. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...

  6. Electrical cable - Wikipedia

    en.wikipedia.org/wiki/Electrical_cable

    6 inch (15 cm) outside diameter, oil-cooled cables, traversing the Grand Coulee Dam throughout. An example of a heavy cable for power transmission. Fire test in Sweden, showing fire rapidly spreading through the burning of cable insulation, a phenomenon of great importance for cables used in some installations. 500,000 circular mil (254 mm 2) single conductor power cable

  7. Thermoplastic-sheathed cable - Wikipedia

    en.wikipedia.org/wiki/Thermoplastic-sheathed_cable

    In North America, this type of cable is designated as NM cable. NM means "nonmetallic", referring to the outer sheathing; the conductors are still metallic. NM was first listed and described in the NEC in 1926, but it was invented a few years earlier by the Rome Wire Company in 1922 in Rome, New York, and marketed under the trade name "Romex". [2]