The CJ-Series Joists are capable of supporting larger floor or roof loadings due to the attachment of the concrete slab to the top chord of the composite joist. Shear connection between the concrete slab and steel joist is typically made by the welding of shear studs through the steel deck to the underlying CJ-Series Composite Steel Joist. [2]
The underlying unit of size given in ISO 2848 for modular coordination is the 'basic module'. [1] The 'basic module' is represented in the standards by the letter M, and has two standard definitions. It is primarily defined as 100 mm (3.937 inches), with the proviso that in countries using imperial units it is defined as 4 inches (101.6 mm).
A double floor is a floor framed with joists supported by larger timbers.. In traditional timber framing there may be a single set of joists which carry both a floor and ceiling called a single floor (single joist floor, single framed floor) or two sets of joists, one carrying the floor and another carrying the ceiling called a double floor (double framed floor).
The chord size and web configuration are determined by span, load and spacing. The parallel chord truss, or flat truss, gets its name from its parallel top and bottom chords. It is often used for floor construction. A combination of the two is a truncated truss, used in hip roof construction.
In light-frame construction, a trimmer is a timber or metal beam (joist) used to create an opening around a stairwell, skylight, chimney, and the like. Trimmers are installed parallel to the primary floor or ceiling joists and support headers , which run perpendicular to the primary joists.
In dimensioned lumber construction, the rim joists are the same depth, thickness and material as the joists themselves; in engineered wood construction, the rim joists may be oriented strand board (OSB), plywood or an engineered wood material varying in thickness from 1 inch (25 mm) to as much as 1 + 3 ⁄ 4 inches (44 mm), though they are ...
The width of the ribs is typically 130 mm (5 in) to 150 mm (6 in), and ribs usually have steel rod reinforcements. [5] The distance between ribs is typically 915 mm (3 ft). [3] The height of the ribs and beams should be 1 ⁄ 25 of the span between columns. [3] The width of the solid area around the column should be 1 ⁄ 8 of
A cost plus contract states that a client agrees to reimburse a construction company for building expenses such as labor, materials, and other costs, plus additional payment usually stated as a percentage of the contract's full price. This type of construction contract is an alternative to lump sum agreements.