enow.com Web Search

  1. Ad

    related to: how to measure superheat hvac window

Search results

  1. Results from the WOW.Com Content Network
  2. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.

  3. Superheated steam - Wikipedia

    en.wikipedia.org/wiki/Superheated_steam

    Superheated steam was widely used in main line steam locomotives. Saturated steam has three main disadvantages in a steam engine: it contains small droplets of water which have to be periodically drained from the cylinders; being precisely at the boiling point of water for the boiler pressure in use, it inevitably condenses to some extent in the steam pipes and cylinders outside the boiler ...

  4. Thermal transmittance - Wikipedia

    en.wikipedia.org/wiki/Thermal_transmittance

    The frame and double sealing of the window system are the actual weak points in the window insulation. Typical thermal transmittance values for common building structures are as follows: [citation needed] Single glazing: 5.7 W/(m 2 ⋅K) Single glazed windows, allowing for frames: 4.5 W/(m 2 ⋅K) Double glazed windows, allowing for frames: 3.3 ...

  5. Cooling load - Wikipedia

    en.wikipedia.org/wiki/Cooling_load

    The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...

  6. Heat pump and refrigeration cycle - Wikipedia

    en.wikipedia.org/wiki/Heat_pump_and...

    Thermodynamic heat pump cycles or refrigeration cycles are the conceptual and mathematical models for heat pump, air conditioning and refrigeration systems. [1] A heat pump is a mechanical system that transmits heat from one location (the "source") at a certain temperature to another location (the "sink" or "heat sink") at a higher temperature. [2]

  7. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    A duct leakage tester is a diagnostic tool designed to measure the airtightness of forced air heating, ventilating and air-conditioning (HVAC) ductwork. A duct leakage tester consists of a calibrated fan for measuring an air flow rate and a pressure sensing device to measure the pressure created by the fan flow.

  8. Superheater - Wikipedia

    en.wikipedia.org/wiki/Superheater

    The steam is then passed through a number of superheater elements, which are long pipes placed inside the larger diameter fire tubes, called flues. Hot combustion gases from the locomotive's fire pass through the flues and, as well as heating the water in the surrounding boiler, they heat the steam inside the superheater elements they flow over.

  9. Operative temperature - Wikipedia

    en.wikipedia.org/wiki/Operative_temperature

    Operative temperature is used in heat transfer and thermal comfort analysis in transportation and buildings. [10] Most psychrometric charts used in HVAC design only show the dry bulb temperature on the x-axis(abscissa), however, it is the operative temperature which is specified on the x-axis of the psychrometric chart illustrated in ANSI/ASHRAE Standard 55 – Thermal Environmental Conditions ...