When the temperature is 30 °C (86 °F) and the dew point is 15 °C (59 °F), the humidex is 34. If the temperature remains 30 °C (86 °F) and the dew point rises to 25 °C (77 °F), the humidex rises to 42. The humidex is higher than the U.S. heat index at equal temperature and relative humidity. The humidex formula is as follows: [7] [8]
The US Occupational Safety and Health Administration recommends indoor air be maintained at 20–24.5 °C (68–76 °F) with a 20–60% relative humidity, [12] equivalent to a dew point of approximately 4.0 to 16.5 °C (39 to 62 °F) (by Simple Rule calculation below). Lower dew points, less than 10 °C (50 °F), correlate with lower ambient ...
Schematic of the LCL in relation to the temperature (T) and dew point and their altitude (Z); the moist adiabatic temperature curve above the LCL is also sketched for reference The lifting condensation level or lifted condensation level ( LCL ) is the height at which the relative humidity (RH) of an air parcel will reach 100% with respect to ...
For premium support please call: 800-290-4726 more ways to reach us
T w = Natural wet-bulb temperature (combined with dry-bulb temperature indicates humidity) T g = Globe thermometer temperature (measured with a globe thermometer, also known as a black globe thermometer) T d = Dry-bulb temperature (actual air temperature) Temperatures may be in either Celsius or Fahrenheit; Indoors the following formula is used:
Determining relative humidity: The percent relative humidity can be located at the intersection of the vertical dry bulb and diagonally down sloping wet bulb temperature lines. Metric (SI): Using a dry bulb of 25 °C and a wet bulb of 20 °C, read the relative humidity at approximately 63.5%.
For example, according to the heat index, a relative humidity of 75% at air temperature of 80.0 °F (26.7 °C) would feel like 83.6 ± 1.3 °F (28.7 ± 0.7 °C). [13] [14] Relative humidity is also a key metric used to evaluate when it is appropriate to install flooring over a concrete slab. [clarification needed]
The dry-bulb temperature (DBT) is the temperature of air measured by a thermometer freely exposed to the air, but shielded from radiation. [1] The dry-bulb temperature is the temperature that is usually thought of as air temperature, and it is the true thermodynamic temperature.