ANSI/ASHRAE/IES Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings is an American National Standards Institute (ANSI) standard published by ASHRAE and jointly sponsored by the Illuminating Engineering Society (IES) that provides minimum requirements for energy efficient designs for buildings except for low-rise residential buildings (i.e. single-family homes ...
[4] The model code, IECC, and the standard, ASHRAE 90.1, apply to commercial buildings. [5] [4] [6] The IECC references several ASHRAE Standards, in particular, ASHRAE 90.1 for commercial building construction. [22] Being a part of the ICC’s collection of model codes, the IECC is revised annually and published in full-form every three years.
ASHRAE was founded in 1894 at a meeting of engineers in New York City, formerly headquartered at 345 East 47th Street, and has held an annual meeting since 1895. [4] Until 1954 it was known as the American Society of Heating and Ventilating Engineers (ASHVE); in that year it changed its name to the American Society of Heating and Air-Conditioning Engineers (ASHAE). [5]
There are two major systems to classify ductwork airtightness, one based on European standards, the other based on ASHRAE standard 90.1-2010.Both are based on the leakage airflow rate at a given ductwork pressure divided by the product of the ductwork surface area and the same ductwork pressure raised to the power 0.65.
Space By Space Method. A defined list of many possible space types within a building the associated watts per square foot allowance. For example, ANSI/ASHRAE/IESNA Standard 90.1-2007 allows the Emergency Space of a hospital to be designed for 2.7 watts per square foot, but the Recovery areas of a hospital would be allowed 0.8 watts per square foot.
A module for Appendix G of ASHRAE 90.1-2010 is available, this is used for example in LEED and BREEAM. The integrated radiosity method with single reflection and one measuring point can be used for whole-year daylight analysis and allows modeling daylight-based control strategies (e.g. shading devices, artificial lightening).
The amount of ventilation in an ETS area is equal to the amount of an ETS-free area plus the amount V, where: V = DSD × VA × A/60E V = recommended extra flow rate in CFM (L/s) DSD = design smoking density (estimated number of cigarettes smoked per hour per unit area) VA = volume of ventilation air per cigarette for the room being designed (ft ...
For example, energy codes such as ASHRAE 90.1 and the IECC prescribe U-values. However, R-value is widely used in practice to describe the thermal resistance of insulation products, layers, and most other parts of the building enclosure (walls, floors, roofs).