Search results
Results from the WOW.Com Content Network
Conventionally the term concrete refers only to concrete that is reinforced with iron or steel. However, other materials are often used to reinforce concrete e.g. organic and inorganic fibres, composites in different forms. While compared to its compressive strength, concrete is weak in tension. Thus adding reinforcement increases the strength ...
The name waffle comes from the grid pattern created by the reinforcing ribs. Waffle slabs are preferred for spans greater than 40 feet (12 m), because, for a given mass of concrete, they are much stronger than flat slabs, flat slabs with drop panels, two-way slabs, one-way slabs, and one-way joist slabs. [2] Section of a waffle slab including ...
Waffle slab foundations adhere to International Building Code requirements. By 2008, most states put into effect the changes adopted in the 2006 IBC and, in regards to foundations, the on-grade mat foundation has become a more attractive design because, as an engineered system, it already accommodates the 2008 design recommendations, and required no major modifications to bring it into compliance.
Reinforcing rebar is placed axially in the column to provide additional axial stiffness. Accounting for the additional stiffness of the steel, the nominal loading capacity P n for the column in terms of the maximum compressive stress of the concrete f c ' , the yield stress of the steel f y , the gross cross section area of the column A g , and ...
The configuration (size, position and quantity) of this reinforcement should be supplemented to the element reinforcement design to ensure for adequate capacity of the lifting design. Lifting design is influenced by the steel / concrete interaction of the specific anchor selected. Different load cases are considered by the lifting design ...
Logo of Eurocode 2 An example of a concrete structure. In the Eurocode series of European standards (EN) related to construction, Eurocode 2: Design of concrete structures (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of concrete, reinforced concrete and prestressed concrete structures, using the limit state design philosophy.
Once this is defined, design code gives standard prescriptions for w/c ratio, the cement content, and the thickness of the concrete cover. This approach represents an improvement step for the durability design of reinforced concrete structures, it is suitable for the design of ordinary structures designed with traditional materials (Portland ...
Slabs are one of the greatest consumers of concrete in many buildings, [14] so reducing the slab mass can make a relatively large difference to the environmental impact of a building's construction. Biaxial slabs may be marginally cheaper than solid slabs, partly due to the lower mass.