Search results
Results from the WOW.Com Content Network
U-100 syringe sizes and markings. 1cc (1 mL) Syringe Holds maximum: 100 units [10] Numbered in: 10 unit increments [10] Smallest line measures 2 units: [11] BD [10] ReliOn [12] Monoject [13] (all but 31 gauge needle) Smallest line measures 1 unit: Easy Touch [14] Precision Sure Dose [13] 1/2cc (0.5 mL) Syringe Holds maximum: 50 units [15 ...
The French scale measures the outer diameter of the catheter, not the size of the internal drainage channel (inner diameter). For instance, a two-way catheter of 20 Fr and a three-way catheter of 20 Fr have the same outer diameter, but the three-way catheter has an additional channel for irrigation, reducing the size of its drainage channel.
Vacuum or suction aspiration is a procedure that uses a vacuum source to remove an embryo or fetus through the cervix. The procedure is performed to induce abortion , as a treatment for incomplete spontaneous abortion (otherwise commonly known as miscarriage ) or retained fetal and placental tissue, or to obtain a sample of uterine lining ...
Menstrual extraction (ME) is a type of manual vacuum aspiration technique developed by feminist activists Lorraine Rothman and Carol Downer to pass the entire menses at once. . The non-medicalized technique has been used in small feminist self-help groups since 1971 and has a social role of allowing access to early abortion without needing medical assistance or legal approv
A number of biopsy instruments are in use. The Novak curette is a thin metallic tube with a side opening at the tip; suction with attached syringe can be applied to help to remove tissue. The Pipelle is a more flexible plastic tube with a side opening at the tip. A smaller tube (internal piston) inside the Pipelle is withdrawn to create suction.
Injector pens remove some of the complications of syringes by allowing the pen to be "pushed" against the skin at a 90-degree angle (removing the need to inject at a proper angle as is the case with syringes), as well as by replacing a long, thin plunger of a syringe with a simple button which is depressed and held to inject the dose. [2]
In many hospitals and other health facilities, suction is typically provided by suction regulators, connected to a central medical vacuum supply by way of a pipeline system. The plastic, rigid Yankauer suction tip is one type of tip that may be attached to a suction device. Another is the plastic, nonrigid French or whistle tip catheter.
Pipetting syringes are hand-held devices that combine the functions of volumetric (bulb) pipettes, graduated pipettes, and burettes. They are calibrated to ISO volumetric A grade standards. A glass or plastic pipette tube is used with a thumb-operated piston and PTFE seal which slides within the pipette in a positive displacement operation ...