enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Pressuretrol - Wikipedia

    en.wikipedia.org/wiki/Pressuretrol

    The main setting is accessible from the outside of the controller, but the differential is often located inside the controller box, and typically the cover must be removed by removing a screw to access the differential control. If the main setting is a cut-in setting, then the differential setting sets the cut-out setpoint by adding to the cut ...

  3. eBUS (serial buses) - Wikipedia

    en.wikipedia.org/wiki/EBUS_(serial_buses)

    As the last step of a data exchange, the master finishes a command by sending a synchronization byte SYN (0xaa). This signals to other masters that the bus is available for use again. A byte stuffing rule (0xa9 -> 0xa9 0x00, 0xaa -> 0xa9 0x01) is applied to all other bytes sent, to ensure that 0xaa does not appear on the wire as part of any ...

  4. ASME Boiler and Pressure Vessel Code - Wikipedia

    en.wikipedia.org/wiki/ASME_Boiler_and_Pressure...

    This committee put in the form work for the first edition of the ASME Boiler Code - Rules for the Construction of Stationary Boilers and for the Allowable Working Pressures, which was issued in 1914 and published in 1915. [5] The first edition of the Boiler and Pressure Vessel Code, known as the 1914 edition, was a single 114-page volume.

  5. Glossary of boiler terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_boiler_terms

    erosion of a boiler's plates from the internal water space, particularly where there is a step inside the shell. This was a problem for early boilers made from lapped plates rather than butted plates, and gave rise to many boiler explosions. In later years it was a problem for the non-circular water drums of Yarrow boilers. Handhole

  6. Water heating - Wikipedia

    en.wikipedia.org/wiki/Water_heating

    Where hot-water space heating boilers are installed, domestic hot water cylinders are usually heated indirectly by primary water from the boiler, or by an electric immersion heater (often as backup to the boiler). In the UK these vessels are called indirect cylinders and direct cylinders, respectively. Additionally, if these cylinders form part ...

  7. Boiler feedwater - Wikipedia

    en.wikipedia.org/wiki/Boiler_feedwater

    Boiler water is treated to prevent scaling, corrosion, foaming, and priming. Chemicals are put into boiler water through the chemical feed tank to keep the water within chemical range. These chemicals are mostly oxygen scavengers and phosphates. The boiler water also has frequent blowdowns in order to keep the chloride content down.

  8. Chiller boiler system - Wikipedia

    en.wikipedia.org/wiki/Chiller_boiler_system

    A chiller boiler system is a hydronic system. It uses water instead of air to heat and cool a structure. A properly designed hydronic system is usually more efficient than a standard forced air system. [1] Chiller boiler systems use radiant heating and cooling or fan coil systems to condition a home or business. This allows for multiple zones ...

  9. Boiler feedwater pump - Wikipedia

    en.wikipedia.org/wiki/Boiler_feedwater_pump

    A means had to be provided, of course, to put the initial charge of water into the boiler (before steam power was available to operate the steam-powered feedwater pump). The pump was often a positive displacement pump that had steam valves and cylinders at one end and feedwater cylinders at the other end; no crankshaft was required.