Ads
related to: insulation resistance test acceptable value for home
Search results
Results from the WOW.Com Content Network
Acceptable values of insulation resistance vary depending on circuit purpose, industry, and country. Typically, standards will dictate acceptable values. An insulation resistance test can be used for simple go/no-go testing, or for periodic condition assessment, where routine insulation resistance tests are performed, with the results tracked ...
A dielectric withstand test may be done as a factory test on new equipment, or may be done on apparatus already in service as a routine maintenance test. [2] An insulation test set; in this pattern, a hand-cranked generator provides the high voltage and the scale is directly calibrated in megohms. Voltage withstand testing is done with a high ...
A minimum acceptable resistance value is usually specified (typically in the mega ohm (MΩ) range per circuit tested). Multiple circuits having a common return may be tested simultaneously, provided the minimum allowable resistance value is based on the number of circuits in parallel. Five basic isolation test configurations exist: [3]
Megohmmeter M1101M. A Megohmmeter or insulation resistance tester, is a special type of ohmmeter used to measure the electrical resistance of insulators. [1] Insulating components, for example cable jackets, must be tested for their insulation strength at the time of commissioning and as part of maintenance of high voltage electrical equipment and installations.
VLF tests at IEEE 400.2 test levels do not damage cable systems' 'good' insulation but are used to degrade existing insulation defects to failure during the test rather than in-service. The reasoning is that the low-energy failure of the cable under test results in less collateral damage and a reduced likelihood of unplanned outages due to in ...
Alternatively, measured insulation resistance (IR [12]) values are not less than 1MΩ for Class I and Class II appliances at 500 V d.c., or at 250 V d.c. [13] to avoid the equipment apparently failing the test because the metal oxide varistors (MOVs) or electro-magnetic interference (EMI) suppression triggered, for equipment containing voltage ...
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
Part 2-034: Particular requirements for measurement equipment for insulation resistance and test equipment for electric strength; Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
Ads
related to: insulation resistance test acceptable value for home