  1. Results from the WOW.Com Content Network
  2. Thermostatic mixing valve - Wikipedia

    en.wikipedia.org/wiki/Thermostatic_mixing_valve

    They also shut off rapidly in the event of a hot or cold supply failure to prevent scalding or thermal shock. It is increasingly common practice around the world to regulate the storage water temperature to above 60 °C (140 °F), and to circulate or distribute water at a temperature less than 50 °C (122 °F).

  3. Automatic bleeding valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_bleeding_valve

    The valve must always be installed vertically, usually at the top of a short vertical pipe. If the valve body is filled with water, the float moves upwards and closes the valve. If air collects in the valve body, the waterline lowers, as does the float, and the valve opens to release it. [4]

  4. Water heating - Wikipedia

    en.wikipedia.org/wiki/Water_heating

    A tempering valve mixes enough cold water with the hot water from the heater to keep the outgoing water temperature fixed at a more moderate temperature, often set to 50 °C (122 °F). Without a tempering valve, reduction of the water heater's setpoint temperature is the most direct way to reduce scalding.

  5. Thermostatic radiator valve - Wikipedia

    en.wikipedia.org/wiki/Thermostatic_radiator_valve

    The valve gradually closes as the temperature of the surrounding area increases, limiting the amount of hot water entering the radiator. This allows a maximum temperature to be set for each room. As the valve works by sensing the temperature of the air surrounding it, it is important to ensure that it is not covered by material (such as curtains).

  6. Automatic balancing valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_balancing_valve

    A diaphragm within the valve keeps the outlet pressure constant, and this delivers a constant flow to the terminal. The added advantage of pressure independent control valves is that, when fitted with an actuator, they replace the manual balancing valve and motorized control valve with a single valve, thus reducing installation cost. [citation ...

  7. Tap (valve) - Wikipedia

    en.wikipedia.org/wiki/Tap_(valve)

    Cone valves or ball valves are another alternative. These are commonly found as the service shut-off valves in more-expensive water systems and usually found in gas taps (and, incidentally, the cask beer taps referred to above). They can be identified by their range of motion—only 90°—between fully open and closed.