The R-value is the building industry term [3] for thermal resistance "per unit area." [4] It is sometimes denoted RSI-value if the SI units are used. [5] An R-value can be given for a material (e.g. for polyethylene foam), or for an assembly of materials (e.g. a wall or a window). In the case of materials, it is often expressed in terms of R ...
Research completed in 1984 revealed some factors which were not accounted for in the original publication of the method; these findings were a result of the ASHRAE research project 359. In 1988 ASHRAE Research Project 472 worked to correct these oversights with the introduction of a classification system for walls, roofs, and zones ...
[7] [22] In the 2021 IECC model code, for example, there are provisions that reference ASHRAE 90.1 concerning insulation R-values for opaque parts of the building envelope. [22] As another example, there are provisions in the IECC concerning the length, flow-rate, and insulation of piping as it relates to hot-water heaters in commercial buildings.
Typical R-values are given for various materials and structures as approximations based on the average of available figures and are sorted by lowest value. R-value at 1 m gives R-values normalised to a 1 metre (3 ft 3 in) thickness and sorts by median value of the range.
All thermal insulation requirements in ASHRAE 90.1 are divided by the climate zone, it means that the amount of insulation needed for a building is determined by which climate zone the building locates. The thermal insulation requirements are shown as R-value and continuous insulation R-value as the second index. [13]
ANSI/ASHRAE/IES Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings is an American National Standards Institute (ANSI) standard published by ASHRAE and jointly sponsored by the Illuminating Engineering Society (IES) that provides minimum requirements for energy efficient designs for buildings except for low-rise residential buildings (i.e. single-family homes ...
Based on a typical k-value of 0.007 W/(m·K), the R-value of a typical 25-millimetre-thick (1 in) VIP would be 3.5 m 2 ·K/W (20 h·ft 2 ·°F/BTU). To provide the same R-value, 154 millimetres (6 in) of rockwool or 84 millimetres (3 in) of rigid polyurethane foam panel would be required.
Sol-air temperature (T sol-air) is a variable used to calculate cooling load of a building and determine the total heat gain through exterior surfaces.It is an improvement over: