Search results
Results from the WOW.Com Content Network
In addition, calibration is used in statistics with the usual general meaning of calibration. For example, model calibration can be also used to refer to Bayesian inference about the value of a model's parameters, given some data set, or more generally to any type of fitting of a statistical model .
As an example, a manual process may be used for calibration of a pressure gauge. The procedure requires multiple steps, [ 12 ] to connect the gauge under test to a reference master gauge and an adjustable pressure source, to apply fluid pressure to both reference and test gauges at definite points over the span of the gauge, and to compare the ...
The ASTM has several procedures for evaluating measurement systems and test methods, including: ASTM E2782 - Standard Guide for Measurement System Analysis; ASTM D4356 - Standard Practice for Establishing Consistent Test Method Tolerances; ASTM E691 - Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test ...
An example of a Levey–Jennings chart with upper and lower limits of one and two times the standard deviation. A Levey–Jennings chart is a graph that quality control data is plotted on to give a visual indication whether a laboratory test is working well. The distance from the mean is measured in standard deviations.
A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
A set of gauge blocks are used as a working standard to check the calibration of measurement tools such as micrometers.. An example of a primary standard was the international prototype of the kilogram (IPK) which was the master kilogram and the primary mass standard for the International System of Units (SI).
These checkweighers are known also as belt weighers, in-motion scales, conveyor scales, dynamic scales, and in-line scales. In filler applications, they are known as check scales. Typically, there are three belts or chain beds: An infeed belt that may change the speed of the package and to bring it up or down to a speed required for weighing.
Certified reference materials (CRMs) are 'controls' or standards used to check the quality and metrological traceability of products, to validate analytical measurement methods, or for the calibration of instruments. [1] A certified reference material is a particular form of measurement standard.