Search results
Results from the WOW.Com Content Network
In analytical chemistry, the detection limit, lower limit of detection, also termed LOD for limit of detection or analytical sensitivity (not to be confused with statistical sensitivity), is the lowest quantity of a substance that can be distinguished from the absence of that substance (a blank value) with a stated confidence level (generally 99%).
A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
Stripping analysis has the following properties: sensitive and reproducible (RSD<5%) method for trace metal ion analysis in aqueous media, 2) concentration limits of detection for many metals are in the low ppb to high ppt range (S/N=3) and this compares favorably with AAS or ICP analysis, field deployable instrumentation that is inexpensive ...
Using a spectrophotometer, it is possible to quantitatively determine the nitrite concentration. The detection limit of the Griess test generally ranges between 0.02 and 2 μM, depending on the exact details of the specific components used in the Griess reagent.
Etendue and ideal concentration. The limit on maximum concentration (shown) is an optic with an entrance aperture S, in air (n i = 1) collecting light within a solid angle of angle 2α (its acceptance angle) and sending it to a smaller area receiver Σ immersed in a medium of refractive index n, whose points are illuminated within a solid angle ...
Tunable diode laser absorption spectroscopy (TDLAS, sometimes referred to as TDLS, TLS or TLAS [1]) is a technique for measuring the concentration of certain species such as methane, water vapor and many more, in a gaseous mixture using tunable diode lasers and laser absorption spectrometry.
Differential pulse voltammetry has these characteristics: 1) reversible reactions have symmetric peaks, and irreversible reactions have asymmetric peaks, 2) the peak potential is equal to E 1/2 r-ΔE in reversible reactions, and the peak current is proportional to the concentration, 3) The detection limit is about 10 −8 M. [citation needed]
The odor detection threshold and the odor recognition threshold are absolute thresholds; the first is the minimum concentration at which an odor can be detected without any requirements to identify or recognize the stimulus, while the second is the minimum concentration at which a stimulus can be identified or recognized. [2]