enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Corneal pachymetry - Wikipedia

    en.wikipedia.org/wiki/Corneal_pachymetry

    Corneal pachymetry is the process of measuring the thickness of the cornea.A pachymeter is a medical device used to measure the thickness of the eye's cornea.It is used to perform corneal pachymetry prior to refractive surgery, for Keratoconus screening, LRI surgery [1] and is useful in screening for patients suspected of developing glaucoma among other uses.

  3. Cornea - Wikipedia

    en.wikipedia.org/wiki/Cornea

    Download as PDF; Printable version ... The cornea is the transparent front part of the ... the cornea has a diameter of about 11.5 mm and a thickness of 0.5–0.6 mm ...

  4. Keratometer - Wikipedia

    en.wikipedia.org/wiki/Keratometer

    The Javal-Schiotz keratometer is a two position instrument which uses a fixed image and doubling size and adjustable object size to determine the radius of curvature of the reflective surface. It uses two self illuminated mires (the object), one a red square, the other a green staircase design, which are held on a circumferential track in order ...

  5. List of optometric abbreviations - Wikipedia

    en.wikipedia.org/wiki/List_of_optometric...

    Visual acuity with Distant chart with correctors Visual acuity with eye chart at Distant 20 feet (6 m) and with (cc: Latin cum correctore) correctors (spectacles); Dsc is without (sc: Latin sine correctore) correctors. See Visual_acuity#Legal_definitions: VA Nsc - VA Ncc Visual acuity with Near chart without correctors

  6. Intraocular lens power calculation - Wikipedia

    en.wikipedia.org/wiki/Intraocular_lens_power...

    The central corneal power is the second important factor in the calculation formula. To simplify the calculation, the cornea is assumed to be a thin spherical lens with a fixed anterior to posterior corneal curvature ratio and an index of refraction of 1.3375. Central corneal power can be measured by keratometry or corneal topography.

  7. Ocular tonometry - Wikipedia

    en.wikipedia.org/wiki/Ocular_tonometry

    When the area of a circle with diameter 3.06 mm (0.120 in) has been flattened, the opposing forces of corneal rigidity and the tear film are roughly approximate and cancel each other out allowing the pressure in the eye to be determined from the force applied. Like all non-invasive methods, it is inherently imprecise and may need to be adjusted.

  8. Goldmann Applanation Tonometer - Wikipedia

    en.wikipedia.org/wiki/Goldmann_Applanation_Tonometer

    Theoretically, average corneal rigidity (taken as 520 μm for GAT) and the capillary attraction of the tear meniscus cancel each other out when the flattened area has the 3.06 mm diameter contact surface of the Goldmann prism, which is applied to the cornea using the Goldmann tonometer with a measurable amount of force from which the IOP is ...

  9. Stroma of cornea - Wikipedia

    en.wikipedia.org/wiki/Stroma_of_cornea

    They are each about 1.5-2.5 μm in thickness. The anterior lamellae interweave more than posterior lamellae. The fibrils of each lamella are parallel with one another, but at different angles to those of adjacent lamellae. The lamellae are produced by keratocytes (corneal connective tissue cells), which occupy about 10% of the substantia propria.