In the event of priming (and also when steam is admitted through cold piping or into a cold cylinder) the operators need to open the cylinder cocks, which are designed to release trapped water. Once occurring, the problem can affect the level indicated in the boiler's gauge glass and for this reason is difficult to put right without reducing ...
Boiler water is liquid water within a boiler, or in associated piping, pumps and other equipment, that is intended for evaporation into steam.The term may also be applied to raw water intended for use in boilers, treated boiler feedwater, steam condensate being returned to a boiler, or boiler blowdown being removed from a boiler.
A steam boiler evaporates liquid water to form steam, or gaseous water, and requires frequent replenishment of boiler feedwater for the continuous production of steam required by most boiler applications. Water is a capable solvent, and will dissolve small amounts of solids from piping and containers including the boiler.
Boiler feedwater is the water which is supplied to a boiler. The feed water is put into the steam drum from a feed pump. In the steam drum the feed water is then turned into steam from the heat. After the steam is used, it is then dumped to the main condenser. From the condenser, it is then pumped to the deaerated feed tank.
The fusible plugs, usually located in the highest part of the crown sheet, have a soft metal alloy core which melts out if the water level in the boiler gets too low. Steam and water blowing into the firebox both alerts the locomotive crew to the low water condition and helps put out the fire. Not all locomotives are equipped with fusible plugs.
Water gauge on a steam locomotive. Here the water is at the “top nut”, the maximum working level. Note the patterned backplate to help reading and toughened glass shroud. A sight glass or water gauge is a type of level sensor, a transparent tube through which the operator of a tank or boiler can observe the level of liquid contained within.
A non-return valve allowing atmospheric air into the boiler, if a cold boiler reduces its internal pressure on cooling down. This avoids the risk of damage to some types, if their pressure loads are reversed. Few boilers are fitted with these, although the feedwater clack valve usually has a similar effect. Vertical boiler Water-level Water-wall
For a vehicle application expected to traverse hills, such as a railway locomotive or steam wagon, maintaining the correct water level when the vehicle itself is not level is a skilled task, and one that occupies much of the fireman's time. In a vertical boiler, the water is all sitting on the top of the firebox, and the boiler would need to be ...