Chromatographic peak resolution is given by = + where t R is the retention time and w b is the peak width at baseline. The bigger the time-difference and/or the smaller the bandwidths, the better the resolution of the compounds. Here compound 1 elutes before compound 2.
3) Changing α is the most effective way of increasing resolution. This can be done by choosing a stationary phase that has a greater difference between k 1 ' and k 2 '. It can also be done in L.C. by using pH to invoke secondary equilibria (if applicable). The fundamental resolution equation is derived as follows:
The Purnell equation is an equation used in analytical chemistry to calculate the resolution R s between two peaks in a chromatogram. [1] [2]= (′ + ′) where R s is the resolution between the two peaks
The greater the separation factor value is over 1.0, the better the separation, until about 2.0 beyond which an HPLC method is probably not needed for separation. Resolution equations relate the three factors such that high efficiency and separation factors improve the resolution of component peaks in an HPLC separation.
A mass chromatogram is a representation of mass spectrometry data as a chromatogram, where the x-axis represents time and the y-axis represents signal intensity. [1] The source data contains mass information; however, it is not graphically represented in a mass chromatogram in favor of visualizing signal intensity versus time.
A high value for resolution corresponding to good separation of peaks is similar to the convention used with chromatography separations, [13] although it is important to note that the definitions are not the same. [14] High resolution indicating better peak separation is also used in ion mobility spectrometry. [15]
Swiss Mass Abacus is a calculator of peptide and glycopeptide masses. It is purposefully kept as simple as a basic calculator executing arithmetic operations. TOF-DS Proprietary: Software by Markes International used with BenchTOF time-of-flight mass spectrometers. TopFD Open source
The conventional method to evaluate the resolution of a tomography reconstruction is determined by the Crowther criterion. [1] [2] The minimum number of views, m, to reconstruct a particle of diameter D to a resolution of d (=1/R) is given by =.