Search results
Results from the WOW.Com Content Network
Transcutaneous pacing is no longer indicated for the treatment of asystole (cardiac arrest associated with a "flat line" on the ECG), with the possible exception of witnessed asystole (as in the case of bifascicular block that progresses to complete heart block without an escape rhythm).
Cardioversion is a medical procedure by which an abnormally fast heart rate (tachycardia) or other cardiac arrhythmia is converted to a normal rhythm using electricity or drugs. Synchronized electrical cardioversion uses a therapeutic dose of electric current to the heart at a specific moment in the cardiac cycle , restoring the activity of the ...
An implantable cardioverter-defibrillator (ICD) or automated implantable cardioverter defibrillator (AICD) is a device implantable inside the body, able to perform defibrillation, and depending on the type, cardioversion and pacing of the heart. The ICD is the first-line treatment and prophylactic therapy for patients at risk for sudden cardiac ...
Patients who are relatively older, who need ICD for secondary prevention, or who have concomitant bradycardia requiring pacing, or heart failure requiring cardiac resynchronisation therapy are more suitable for transvenous ICD implantation. An older patient with ischemic cardiomyopathy and documented symptomatic ventricular tachycardia is a ...
If defibrillation is required, the machine is charged, and the shock is delivered, without any need to apply any additional gel or to retrieve and place any paddles. Most adhesive electrodes are designed to be used not only for defibrillation, but also for transcutaneous pacing and synchronized electrical cardioversion. These adhesive pads are ...
The ICD-10 Procedure Coding System (ICD-10-PCS) is a US system of medical classification used for procedural coding.The Centers for Medicare and Medicaid Services, the agency responsible for maintaining the inpatient procedure code set in the U.S., contracted with 3M Health Information Systems in 1995 to design and then develop a procedure classification system to replace Volume 3 of ICD-9-CM.
Guidelines and indications are specific to different patient populations. For adults with aortic stenosis, guidelines suggest that balloon aortic valvuloplasty (BAV) is to be used as a temporary procedure to improve blood flow through the aortic valve to alleviate symptoms and stabilize clinically before having more invasive procedures done, including aortic valve replacement (AVR) or ...
An ICD has the ability to treat many types of heart rhythm disturbances by means of pacing, cardioversion, or defibrillation. Some ICD devices can distinguish between ventricular fibrillation and ventricular tachycardia (VT), and may try to pace the heart faster than its intrinsic rate in the case of VT, to try to break the tachycardia before ...