enow.com Web Search

  1. Ad

    related to: cooling tower water standard parameters chart

Search results

  1. Results from the WOW.Com Content Network
  2. Cooling tower - Wikipedia

    en.wikipedia.org/wiki/Cooling_tower

    Though the total particulate emissions from wet cooling towers with fresh water make-up is much less, they contain more PM 10 and PM 2.5 than the total emissions from wet cooling towers with sea water make-up. This is due to lesser salt content in fresh water drift (below 2,000 ppm) compared to the salt content of sea water drift (60,000 ppm).

  3. Water (data page) - Wikipedia

    en.wikipedia.org/wiki/Water_(data_page)

    Data in the table above is given for water–steam equilibria at various temperatures over the entire temperature range at which liquid water can exist. Pressure of the equilibrium is given in the second column in kPa. The third column is the heat content of each gram of the liquid phase relative to water at 0 °C.

  4. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.

  5. Evaporative cooler - Wikipedia

    en.wikipedia.org/wiki/Evaporative_cooler

    For example, a 371 m 2 (4,000 ft 2) retail store in Tucson, Arizona with a sensible heat gain of 29.3 kJ/h (100,000 Btu/h) can be cooled entirely by two passive cooling towers providing 11890 m 3 /h (7,000 cfm) each. [15] For the Zion National Park visitors' center, which uses two passive cooling towers, the cooling energy intensity was 14.5 MJ ...

  6. Steam and water analysis system - Wikipedia

    en.wikipedia.org/wiki/Steam_and_water_analysis...

    This can be achieved by two-stage cooling. In the first stage cooling (also known as 'primary cooling'), the sample is cooled by using available cooling water. In most of the countries, cooling water is available in the range of 30–32 °C. This cooling water can cool the sample unto 35 °C(considering an approach temperature of 3 to 5 °C).

  7. Chilled water - Wikipedia

    en.wikipedia.org/wiki/Chilled_water

    The cooling towers of a large chilled water system. As part of a chilled water system, the condenser water absorbs heat from the refrigerant in the condenser barrel of the water chiller and is then sent via return lines to a cooling tower, which is a heat exchange device used to transfer waste heat to the atmosphere.

  8. European seasonal energy efficiency ratio - Wikipedia

    en.wikipedia.org/wiki/European_seasonal_energy...

    A similar standard in the United States is the integrated energy efficiency ratio (IEER). The ESEER is calculated by combining full and part load operating Energy Efficiency Ratios (EER), for different seasonal air or water temperatures, and including for appropriate weighting factors. These values are shown in the following table.

  9. Chilled beam - Wikipedia

    en.wikipedia.org/wiki/Chilled_beam

    A chilled beam is a type of radiation/convection HVAC system designed to heat and cool large buildings through the use of water. [1] This method removes most of the zone sensible local heat gains and allows the flow rate of pre-conditioned air from the air handling unit to be reduced, lowering by 60% to 80% the ducted design airflow rate and the equipment capacity requirements.

  1. Ad

    related to: cooling tower water standard parameters chart