The study of the behavior of air-water vapor mixtures. Water vapor plays an important role in energy transfer and human comfort in HVAC design. rooftop unit (RTU) A packaged unit that controls both heating and air conditioning. An air handler typically refers to a unit that provides a fan to support either heating or cooling. radiant ceiling panels
The supply pipe supplies either cold or hot water to the unit depending on the time of year. Four-pipe fan coil units have two supply pipes and two return pipes. This allows either hot or cold water to enter the unit at any given time. Since it is often necessary to heat and cool different areas of a building at the same time, due to ...
Figure 1: Components of a centrifugal fan An external motor belt driven inline centrifugal fan discharging inline to the exterior of a building through a duct. Unlike non-inline/non-concentric impeller casing design with a cutoff blade above, the concentrically symetric cylinder casing and impeller geometry of inline type redirects the outflow around so that it is parallel to the inflow of gases.
HVAC ventilation exhaust for a 12-story building An axial belt-drive exhaust fan serving an underground car park. This exhaust fan's operation is interlocked with the concentration of contaminants emitted by internal combustion engines. Mechanical, or forced, ventilation is provided by an air handler (AHU) and used to control indoor air quality.
Round duct is made using a continuous spiral forming machine which can make round duct in nearly any diameter when using the right forming die and to any length to suit, but the most common stock sizes range evenly from 4" to 24" (10-60 cm) with 6"-12" (15-30 cm) being most commonly used. Stock pipe is usually sold in 10' (300 cm) joints.
Air can be exhausted through pressurized hoods or the use of fans and pressurizing a specific area. [35] A local exhaust system is composed of five basic parts: A hood that captures the contaminant at its source; Ducts for transporting the air; An air-cleaning device that removes/minimizes the contaminant; A fan that moves the air through the ...
However, since double pipe heat exchangers are simple, they are used to teach heat exchanger design basics to students as the fundamental rules for all heat exchangers are the same. 1. Double-pipe heat exchanger When one fluid flows through the smaller pipe, the other flows through the annular gap between the two pipes.
Opposed blade dampers in a mixing duct. A damper is a valve or plate that stops or regulates the flow of air inside a duct , chimney , VAV box , air handler , or other air-handling equipment. A damper may be used to cut off central air conditioning (heating or cooling) to an unused room, or to regulate it for room-by-room temperature and ...