Search results
Results from the WOW.Com Content Network
In electrical engineering, current sensing is any one of several techniques used to measure electric current. The measurement of current ranges from picoamps to tens of thousands of amperes. The selection of a current sensing method depends on requirements such as magnitude, accuracy, bandwidth, robustness, cost, isolation or size. The current ...
A chemical sensor array is a sensor architecture with multiple sensor components that create a pattern for analyte detection from the additive responses of individual sensor components. There exist several types of chemical sensor arrays including electronic, optical, acoustic wave, and potentiometric devices.
The Tafel equation describes the dependence of current for an electrolytic process to overpotential. The exchange current density is the current in the absence of net electrolysis and at zero overpotential. The exchange current can be thought of as a background current to which the net current observed at various overpotentials is normalized.
Four-point measurement of resistance between voltage sense connections 2 and 3. Current is supplied via force connections 1 and 4. In electrical engineering, four-terminal sensing (4T sensing), 4-wire sensing, or 4-point probes method is an electrical impedance measuring technique that uses separate pairs of current-carrying and voltage-sensing electrodes to make more accurate measurements ...
Furthermore, as the nickel content increases, so does the voltage and the mAh/g charge that can be stored in the battery. This is because Co is cycled in a battery between oxidation states +3 and +3.5 (i.e. with 0.5 electron/cobalt atom), while nickel can go between +3 and +4 (i.e. 1 electron/nickel atom).
A silver oxide battery (IEC code: S) is a primary cell using silver oxide as the cathode material and zinc for the anode. These cells maintain a nearly constant nominal voltage during discharge until fully depleted. [ 2 ]
Coulometry uses applied current or potential to convert an analyte from one oxidation state to another completely. In these experiments, the total current passed is measured directly or indirectly to determine the number of electrons passed. Knowing the number of electrons passed can indicate the concentration of the analyte or when the ...
The current is measured only while the working potential is applied, then sequential current measurements are processed by the detector to produce a smooth output. PAD is most often used for detection of carbohydrates after an anion exchange separation, but further development of related techniques show promise for amines, reduced sulfur ...