Search results
Results from the WOW.Com Content Network
Chromatographic peak resolution is given by = + where t R is the retention time and w b is the peak width at baseline. The bigger the time-difference and/or the smaller the bandwidths, the better the resolution of the compounds.
In liquid chromatography, the mobile phase velocity is taken as the exit velocity, that is, the ratio of the flow rate in ml/second to the cross-sectional area of the ‘column-exit flow path.’ For a packed column, the cross-sectional area of the column exit flow path is usually taken as 0.6 times the cross-sectional area of the column.
Size-exclusion chromatography, also known as molecular sieve chromatography, [1] is a chromatographic method in which molecules in solution are separated by their shape, and in some cases size. [2] It is usually applied to large molecules or macromolecular complexes such as proteins and industrial polymers . [ 3 ]
The thermal conductivity detector (TCD), also known as a katharometer, is a bulk property detector and a chemical specific detector commonly used in gas chromatography. [1] This detector senses changes in the thermal conductivity of the column eluent and compares it to a reference flow of carrier gas. Since most compounds have a thermal ...
A high value for resolution corresponding to good separation of peaks is similar to the convention used with chromatography separations, [13] although it is important to note that the definitions are not the same. [14] High resolution indicating better peak separation is also used in ion mobility spectrometry. [15]
By measuring any two of these solutions, the unknown concentration is calculated. [1] As polarographic standard addition involves using only one solution with the standard added – the two-level design, polarographers always refer to the method as singular, standard addition. [4]
Chromatography software is called also Chromatography Data System. [1] It is located in the data station of the modern liquid, gas or supercritical fluid chromatographic systems. This is a dedicated software connected to an hardware interface within the chromatographic system, which serves as a central hub for collecting, analyzing, and ...
(For instance, if the first column offers a peak capacity (k 1)of 100 for a 10-minute separation, and the second column offers a peak capacity of 5 (k 2) in a 5-second separation, then the combined peak capacity may approach k 1 × k 2 =500, with the total separation time still ~ 10 minutes). 2D separations have been applied to the analysis of ...