In liquid chromatography, the mobile phase velocity is taken as the exit velocity, that is, the ratio of the flow rate in ml/second to the cross-sectional area of the ‘column-exit flow path.’ For a packed column, the cross-sectional area of the column exit flow path is usually taken as 0.6 times the cross-sectional area of the column.
Chromatographic peak resolution is given by = + where t R is the retention time and w b is the peak width at baseline. The bigger the time-difference and/or the smaller the bandwidths, the better the resolution of the compounds. Here compound 1 elutes before compound 2.
The valley definition defines ΔM as the closest spacing of two peaks of equal intensity with the valley (lowest value of signal) between them less than a specified fraction of the peak height. Typical values are 10% or 50%. The value obtained from a 5% peak width is roughly equivalent to a 10% valley. [1]
The peak is "well-sampled", so that less than 10% of the area or volume under the peak (area if a 1D Gaussian, volume if a 2D Gaussian) lies outside the measurement region. The width of the peak is much larger than the distance between sample locations (i.e. the detector pixels must be at least 5 times smaller than the Gaussian FWHM).
Chromatography software is called also Chromatography Data System. [1] It is located in the data station of the modern liquid, gas or supercritical fluid chromatographic systems. This is a dedicated software connected to an hardware interface within the chromatographic system, which serves as a central hub for collecting, analyzing, and ...
OpenChrom is an open source software for the analysis and visualization of mass spectrometric and chromatographic data. [4] Its focus is to handle native data files from several mass spectrometry systems (e.g. GC/MS, LC/MS, Py-GC/MS, HPLC-MS), vendors like Agilent Technologies, Varian, Shimadzu, Thermo Fisher, PerkinElmer and others.
The charged aerosol detector (CAD) is a detector used in conjunction with high-performance liquid chromatography (HPLC) and ultra high-performance liquid chromatography (UHPLC) to measure the amount of chemicals in a sample by creating charged aerosol particles which are detected using an electrometer.
A microchannel plate (MCP) is used to detect single particles (electrons, ions and neutrons [1]) and photons (ultraviolet radiation and X-rays).It is closely related to an electron multiplier, as both intensify single particles or photons by the multiplication of electrons via secondary emission. [2]