enow.com Web Search

  1. Ads

    related to: what is cooling and dehumidification temperature

Search results

  1. Results from the WOW.Com Content Network
  2. Dehumidifier - Wikipedia

    en.wikipedia.org/wiki/Dehumidifier

    Dehumidifiers are designed to pass air directly over the cooling coils and then the heating coils in a single efficient pass through the device. In addition, most air conditioners are controlled by a thermostat which senses temperature, rather than a humidistat that senses humidity and is typically used to control a dehumidifier.

  3. Moisture removal efficiency - Wikipedia

    en.wikipedia.org/wiki/Moisture_removal_efficiency

    DOAS Diagram. Moisture Removal Efficiency (MRE) is a measure of the energy efficiency of any dehumidification process. Moisture removal efficiency is the water vapor removed from air at a defined inlet air temperature and humidity, divided by the total energy consumed by the dehumidification equipment during the same time period, including all fan and pump energy needed to move air and fluids ...

  4. Wet-bulb temperature - Wikipedia

    en.wikipedia.org/wiki/Wet-bulb_temperature

    The wet-bulb temperature is the lowest temperature that may be achieved by evaporative cooling of a water-wetted, ventilated surface.. By contrast, the dew point is the temperature to which the ambient air must be cooled to reach 100% relative humidity assuming there is no further evaporation into the air; it is the temperature where condensation (dew) and clouds would form.

  5. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    Dehumidification (air drying) in an air conditioning system is provided by the evaporator. Since the evaporator operates at a temperature below the dew point , moisture in the air condenses on the evaporator coil tubes.

  6. Cooling load - Wikipedia

    en.wikipedia.org/wiki/Cooling_load

    The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...

  7. Cromer cycle - Wikipedia

    en.wikipedia.org/wiki/Cromer_cycle

    For a typical air conditioning system, this air at state point 1 enters the cooling coil and leaves at about state point 4' after cooling and drying. State point 4' represents the temperature and moisture content of the air that leaves the typical unit, about 45–50 °F (7–10 °C) and 95–98% RH.

  8. Air conditioning - Wikipedia

    en.wikipedia.org/wiki/Air_conditioning

    Air conditioning, often abbreviated as A/C (US) or air con (UK), [1] is the process of removing heat from an enclosed space to achieve a more comfortable interior temperature and in some cases also controlling the humidity of internal air.

  9. Humidity - Wikipedia

    en.wikipedia.org/wiki/Humidity

    This is because the vapor pressure of water increases with temperature—the operative principle behind everything from hair dryers to dehumidifiers. Due to the increasing potential for a higher water vapor partial pressure at higher air temperatures, the water content of air at sea level can get as high as 3% by mass at 30 °C (86 °F ...

  1. Ads

    related to: what is cooling and dehumidification temperature