enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Load profile - Wikipedia

    en.wikipedia.org/wiki/Load_Profile

    The power transformer or battery-to-grid are critical aspects of power distribution and sizing and modelling of batteries or transformers depends on the load profile. [1] The factory specification of transformers for the optimization of load losses versus no-load losses is dependent directly on the characteristics of the load profile that the ...

  3. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  4. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    Primaries provide power at the standard distribution voltages used in the area; these range from as low as 2.3 kV to about 35 kV depending on local distribution practice and standards, often 11 kV (50 Hz systems) and 13.8 kV (60 Hz systems) are used, but many other voltages are standard.

  5. Buck–boost transformer - Wikipedia

    en.wikipedia.org/wiki/Buck–boost_transformer

    Buck–boost transformers can be used to power low voltage circuits including control, lighting circuits, or applications that require 12, 16, 24, 32 or 48 volts, consistent with the design's secondaries. The transformer is connected as an isolating transformer and the nameplate kVA rating is the transformer’s capacity. [2]

  6. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    Fig. 1 Fig. 2. A transformer supplying a three-wire distribution system has a single-phase input (primary) winding. The output (secondary) winding has a center tap connected to a grounded neutral. As shown in Fig. 1, either end to center has half the voltage of end-to-end.

  7. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    The two cylindrical metal cases fit into octal sockets; each one contains a 1:1 line transformer, the first is rated at 600 ohms, the second is rated at 15,000 ohms. On the far right is a DI unit; its 12:1 transformer (with yellow insulation) changes a high impedance unbalanced input to a low impedance balanced output.

  8. Vector group - Wikipedia

    en.wikipedia.org/wiki/Vector_group

    Thus 1 = 30°, 2 = 60°, 3 = 90°, 6 = 180° and 12 = 0° or 360°. According to the IEC60076-1 standard, the notation is HV-LV in sequence. For example, a step-up transformer with a delta-connected primary and a wye-connected secondary is still labeled as 'Yd1'. The 1 indicates the LV winding lags the HV by 30 degrees. [1]

  9. Scott-T transformer - Wikipedia

    en.wikipedia.org/wiki/Scott-T_transformer

    Standard Scott Connection 3 φ to 2 φ. Assuming the desired voltage is the same on the two and three phase sides, the Scott-T transformer connection (shown right) consists of a centre-tapped 1:1 ratio main transformer, T1, and a √ 3 /2(≈86.6%) ratio teaser transformer, T2. The centre-tapped side of T1 is connected between two of the phases ...

  1. Related searches electrical transformer sizing calculator standard to pro series 12 in 1 6 slice toaster oven

    per unit transformer voltagetransformer voltage ratings