enow.com Web Search

  1. Ad

    related to: electrical transformer sizing calculator standard to pro series 12 meat grinder
    • Substation

      Request a quote for a substation

      In stock substation transformers

    • Low Voltage Dry-Type

      Buy a general purpose transformer

      In stock low voltage transformers

    • Get In Touch

      Contact Us Today

      Have Questions? We're Here To Help

    • News

      Check Out The Latest News About

      Maddox Industrial Transformer.

Search results

  1. Results from the WOW.Com Content Network
  2. Load profile - Wikipedia

    en.wikipedia.org/wiki/Load_Profile

    The power transformer or battery-to-grid are critical aspects of power distribution and sizing and modelling of batteries or transformers depends on the load profile. [1] The factory specification of transformers for the optimization of load losses versus no-load losses is dependent directly on the characteristics of the load profile that the ...

  3. Vector group - Wikipedia

    en.wikipedia.org/wiki/Vector_group

    Thus 1 = 30°, 2 = 60°, 3 = 90°, 6 = 180° and 12 = 0° or 360°. According to the IEC60076-1 standard, the notation is HV-LV in sequence. For example, a step-up transformer with a delta-connected primary and a wye-connected secondary is still labeled as 'Yd1'. The 1 indicates the LV winding lags the HV by 30 degrees. [1]

  4. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    Ferro-resonant transformers run hotter than standard power transformers, because regulating action depends on core saturation, which reduces efficiency. The output waveform is heavily distorted unless careful measures are taken to prevent this. Saturating transformers provide a simple rugged method to stabilize an AC power supply.

  5. List of IEC standards - Wikipedia

    en.wikipedia.org/wiki/List_of_IEC_standards

    IEC 60072 Dimensions and output series for rotating electrical machines; IEC 60073 Basic and safety principles for man-machine interface, marking and identification – Coding principles for indicators and actuators; IEC 60076 Power transformers; IEC 60077 Railway applications – Electric equipment for rolling stock; IEC 60079 Explosive ...

  6. Buck–boost transformer - Wikipedia

    en.wikipedia.org/wiki/Buck–boost_transformer

    Buck–boost transformers can be used to power low voltage circuits including control, lighting circuits, or applications that require 12, 16, 24, 32 or 48 volts, consistent with the design's secondaries. The transformer is connected as an isolating transformer and the nameplate kVA rating is the transformer’s capacity. [2]

  7. Pad-mounted transformer - Wikipedia

    en.wikipedia.org/wiki/Pad-mounted_transformer

    ANSI C57.12.00 – Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers ANSI C57.12.22 – Standard for Transformers - Pad-Mounted, Compartmental-Type, Self-Cooled, Three-Phase Distribution Transformers with High-Voltage Bushings, 2500 kVA and Smaller: High Voltage, 34,500Grd/19,920 Volts, and Below ...

  8. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    The invention of a practical, efficient transformer made AC power distribution feasible; a system using distribution transformers was demonstrated as early as 1882. [2] If mounted on a utility pole, they are called pole-mount transformers. Suppose the distribution lines are located at ground level or underground.

  9. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    The phase shift in Europe is 120°, as is the case with three-phase current. That's why we calculate 130V * √3 = 225V. A three-phase final step-down transformer is then used. One house gets phases A & B, the next house gets phase B & C, the third house gets phase A & C.

  1. Ad

    related to: electrical transformer sizing calculator standard to pro series 12 meat grinder