Ads
related to: calculate btu air conditioner formula tablenortherntool.com has been visited by 100K+ users in the past month
- Ventilation Systems
Reduce Moisture In Crawl Spaces
+ Prevent Weather Deterioration.
- Wall Mount + Garage Fans
Durable Metal Construction For Long
Lasting Life. Shop Fans Today!
- Curbside Pickup Available
Buy Online + Take Advantage Of Our
New Contactless Curbside Pickup!
- Pedestal Fans
Ventilate Large Areas Fast With
Pedestal Fans. Shop Today!
- Ventilation Systems
Search results
Results from the WOW.Com Content Network
Btu per hour (Btu/h) is sometimes used in North America and the United Kingdom - the latter for air conditioning mainly, though "Btu/h" is sometimes abbreviated to just "Btu". [18] MBH—thousands of Btu per hour—is also common. [19] 1 W is approximately 3.412142 Btu/h [20] 1,000 Btu/h is approximately 0.2931 kW; 1 hp is approximately 2,544 Btu/h
The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.
12,000.00 Btu IT /h 2,593.90 ft⋅lbf/s A ton of refrigeration ( TR or TOR ), also called a refrigeration ton ( RT ), is a unit of power used in some countries (especially in North America) to describe the heat-extraction capacity of refrigeration and air conditioning equipment.
Air-conditioner sizes are often given as "tons" of cooling, where 1 ton of cooling equals 12,000 BTU/h (3.5 kW). 1 ton of cooling equals the amount of power that needs to be applied continuously over a 24-hour period to melt 1 ton of ice. The annual cost of electric energy consumed by an air conditioner may be calculated as follows:
Cooling capacity is the measure of a cooling system's ability to remove heat. [1] It is equivalent to the heat supplied to the evaporator/boiler part of the refrigeration cycle and may be called the "rate of refrigeration" or "refrigeration capacity".
The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...
The coefficient of performance or COP (sometimes CP or CoP) of a heat pump, refrigerator or air conditioning system is a ratio of useful heating or cooling provided to work (energy) required. [1] [2] Higher COPs equate to higher efficiency, lower energy (power) consumption and thus lower operating costs. The COP is used in thermodynamics.
In those contexts, the unit of heat capacity is 1 BTU/°R ≈ 1900 J/K. [5] The BTU was in fact defined so that the average heat capacity of one pound of water would be 1 BTU/°F. In this regard, with respect to mass, note conversion of 1 Btu/lb⋅°R ≈ 4,187 J/kg⋅K [6] and the calorie (below).
Ads
related to: calculate btu air conditioner formula tablenortherntool.com has been visited by 100K+ users in the past month