Search results

  1. Results from the WOW.Com Content Network
  2. Mass spectral interpretation - Wikipedia

    en.wikipedia.org/wiki/Mass_spectral_interpretation

    In the spectrum for toluene for example, the molecular ion peak is located at 92 m/z corresponding to its molecular mass. Molecular ion peaks are also often preceded by an M-1 or M-2 peak resulting from loss of a hydrogen radical or dihydrogen, respectively. Here, M refers to the molecular mass of the compound.

  3. Sample preparation in mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Sample_preparation_in_mass...

    Sample preparation for mass spectrometry is used for the optimization of a sample for analysis in a mass spectrometer (MS). Each ionization method has certain factors that must be considered for that method to be successful, such as volume, concentration , sample phase, and composition of the analyte solution.

  4. Mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Mass_spectrometry

    Ion mobility spectrometry-mass spectrometry (IMS/MS or IMMS) is a technique where ions are first separated by drift time through some neutral gas under an applied electrical potential gradient before being introduced into a mass spectrometer. [43] Drift time is a measure of the collisional cross section relative to the charge of the ion.

  5. Atmospheric-pressure chemical ionization - Wikipedia

    en.wikipedia.org/wiki/Atmospheric-pressure...

    Atmospheric pressure chemical ionization chamber cross section. Atmospheric pressure chemical ionization (APCI) is an ionization method used in mass spectrometry which utilizes gas-phase ion-molecule reactions at atmospheric pressure (10 5 Pa), [1] [2] commonly coupled with high-performance liquid chromatography (HPLC). [3]

  6. Selected-ion flow-tube mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Selected-ion_flow-tube...

    In the selected ion flow tube mass spectrometer, SIFT-MS, ions are generated in a microwave plasma ion source, usually from a mixture of laboratory air and water vapor. . From the formed plasma, a single ionic species is selected using a quadrupole mass filter to act as "precursor ions" (also frequently referred to as primary or reagent ions in SIFT-MS and other processes involving chemical ...

  7. Liquid chromatography–mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Liquid_chromatography...

    The mass spectrum can be used to determine the mass of the analytes, their elemental and isotopic composition, or to elucidate the chemical structure of the sample. [5] MS is an experiment that must take place in gas phase and under vacuum (1.33 * 10 −2 to 1.33 * 10 −6 pascal).

  8. Mass spectrum - Wikipedia

    en.wikipedia.org/wiki/Mass_spectrum

    A mass spectrum is a histogram plot of intensity vs. mass-to-charge ratio (m/z) in a chemical sample, [1] usually acquired using an instrument called a mass spectrometer. Not all mass spectra of a given substance are the same; for example, some mass spectrometers break the analyte molecules into fragments ; others observe the intact molecular ...

  9. Chlorine dioxide - Wikipedia

    en.wikipedia.org/wiki/Chlorine_dioxide

    The molecule ClO 2 has an odd number of valence electrons, and therefore, it is a paramagnetic radical. It is an unusual "example of an odd-electron molecule stable toward dimerization" (nitric oxide being another example). [5] A unit cell of the orthorhombic ClO 2 crystal shown in an arbitrary direction.