enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Detection limit - Wikipedia

    en.wikipedia.org/wiki/Detection_limit

    In analytical chemistry, the detection limit, lower limit of detection, also termed LOD for limit of detection or analytical sensitivity (not to be confused with statistical sensitivity), is the lowest quantity of a substance that can be distinguished from the absence of that substance (a blank value) with a stated confidence level (generally 99%).

  3. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  4. Electrochemical stripping analysis - Wikipedia

    en.wikipedia.org/wiki/Electrochemical_stripping...

    Stripping analysis has the following properties: sensitive and reproducible (RSD<5%) method for trace metal ion analysis in aqueous media, 2) concentration limits of detection for many metals are in the low ppb to high ppt range (S/N=3) and this compares favorably with AAS or ICP analysis, field deployable instrumentation that is inexpensive ...

  5. Analytical chemistry - Wikipedia

    en.wikipedia.org/wiki/Analytical_chemistry

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL) A general method for analysis of concentration involves the creation of a calibration curve. This allows for the determination of the amount of a chemical in a material by comparing the results of an unknown ...

  6. Differential pulse voltammetry - Wikipedia

    en.wikipedia.org/wiki/Differential_pulse_voltammetry

    Differential pulse voltammetry has these characteristics: 1) reversible reactions have symmetric peaks, and irreversible reactions have asymmetric peaks, 2) the peak potential is equal to E 1/2 r-ΔE in reversible reactions, and the peak current is proportional to the concentration, 3) The detection limit is about 10 −8 M. [citation needed]

  7. Atomic absorption spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Atomic_absorption_spectroscopy

    The mercury, is then swept into a long-pass absorption tube by bubbling a stream of inert gas through the reaction mixture. The concentration is determined by measuring the absorbance of this gas at 253.7 nm. Detection limits for this technique are in the parts-per-billion range making it an excellent mercury detection atomization method.

  8. Tunable diode laser absorption spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Tunable_diode_laser...

    Tunable diode laser absorption spectroscopy (TDLAS, sometimes referred to as TDLS, TLS or TLAS [1]) is a technique for measuring the concentration of certain species such as methane, water vapor and many more, in a gaseous mixture using tunable diode lasers and laser absorption spectrometry.

  9. Neutron activation analysis - Wikipedia

    en.wikipedia.org/wiki/Neutron_activation_analysis

    NAA can detect up to 74 elements depending upon the experimental procedure, with minimum detection limits ranging from 0.1 to 1x10 6 ng g −1 depending on element under investigation. Heavier elements have larger nuclei, therefore they have a larger neutron capture cross-section and are more likely to be activated.