enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Callendar–Van Dusen equation - Wikipedia

    en.wikipedia.org/wiki/Callendar–Van_Dusen_equation

    The Callendar–Van Dusen equation is an equation that describes the relationship between resistance (R) and temperature (T) of platinum resistance thermometers (RTD). As commonly used for commercial applications of RTD thermometers, the relationship between resistance and temperature is given by the following equations.

  3. Resistance thermometer - Wikipedia

    en.wikipedia.org/wiki/Resistance_thermometer

    Time response is measured by immersing the sensor in water moving at 1 m/s (3.3 ft/s) with a 63.2% step change. Size A standard RTD sheath is 3.175 to 6.35 mm (0.1250 to 0.2500 in) in diameter; sheath diameters for thermocouples can be less than 1.6 mm (0.063 in). Accuracy and stability requirements

  4. Time constant - Wikipedia

    en.wikipedia.org/wiki/Time_constant

    An example response of system to sine wave forcing function. Time axis in units of the time constant τ. The response damps out to become a simple sine wave. Frequency response of system vs. frequency in units of the bandwidth f 3dB. The response is normalized to a zero frequency value of unity, and drops to 1/√2 at the bandwidth.

  5. Thermocouple - Wikipedia

    en.wikipedia.org/wiki/Thermocouple

    A thermocouple, also known as a "thermoelectrical thermometer", is an electrical device consisting of two dissimilar electrical conductors forming an electrical junction.A thermocouple produces a temperature-dependent voltage as a result of the Seebeck effect, and this voltage can be interpreted to measure temperature.

  6. Seebeck coefficient - Wikipedia

    en.wikipedia.org/wiki/Seebeck_coefficient

    In thermocouples the Seebeck effect is used to measure temperatures, and for accuracy it is desirable to use materials with a Seebeck coefficient that is stable over time. Physically, the magnitude and sign of the Seebeck coefficient can be approximately understood as being given by the entropy per unit charge carried by electrical currents in ...

  7. Bolometer - Wikipedia

    en.wikipedia.org/wiki/Bolometer

    The average response time of the bolometer allows convenient measurement of the power of a pulsed source. [ 14 ] In 2020, two groups reported microwave bolometers based on graphene-based materials capable of microwave detection at the single-photon level.

  8. Heat flux sensor - Wikipedia

    en.wikipedia.org/wiki/Heat_flux_sensor

    As a rule of thumb, the response time is proportional to the thickness to the power of two. Gardon or Schmidt Boelter gauge showing the instrument main components: metal body, black sensor, water cooling pipe in and out, mounting flange, and cable. Dimensions: diameter housing is 25mm. Photo shows model SBG01. Other parameters that are ...

  9. Round-trip delay - Wikipedia

    en.wikipedia.org/wiki/Round-trip_delay

    In telecommunications, round-trip delay (RTD) or round-trip time (RTT) is the amount of time it takes for a signal to be sent plus the amount of time it takes for acknowledgement of that signal having been received. This time delay includes propagation times for the paths between the two communication endpoints. [1]