Sprinkler fitting is a skilled trade that consists of assembling, installing, testing, repairing, inspecting, and certifying automatic fire suppression systems and their associated piping in commercial, industrial and residential buildings.
Conserve Water During Testing – NFPA-25 requires that the fire pump controller is operated for 10 minutes each week. This ends up using a substantial amount of water in buildings that have static pressures greater than 175 PSI and relies on a system relief valve to control the pressure: (50–100% of the rating of the pump) × (10minutes) × ...
A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used only in factories and large commercial buildings, systems for homes and small buildings are now available ...
The hydraulic calculation procedure is defined in the applicable reference model codes such as that published by the US-based National Fire Protection Association (NFPA), [2] or the EN 12845 standard, Fixed firefighting system – Automatic sprinkler systems – Design, installation and maintenance. [3]
The committee's initial report evolved into NFPA 13, Standard for the Installation of Sprinkler Systems, the most widely used fire sprinkler standard. [ 6 ] Around 1904, the NFPA began to expand its membership from affiliates of fire insurance companies to many other organizations and individuals, and also expanded its mission beyond ...
The publication Life Safety Code, known as NFPA 101, is a consensus standard widely adopted in the United States. [according to whom?] It is administered, trademarked, copyrighted, and published by the National Fire Protection Association and, like many NFPA documents, is systematically revised on a three-year cycle.
They are inspected per NFPA 25 "Inspection and Testing of Water-Based Fire Protection Systems". In India, the pump manufacturers generally adhere to the TAC (Tariff Advisory Committee) guidelines, although pump manufacturers also obtain listings with UL or FM Global. For the purpose of installation & maintenance of fire-fighting pumps, Bureau ...
These standards are widely accepted as the standards of knowledge and skills measurement for all firefighters in North America and beyond. Essentials of Fire Fighting includes an appendix that lists the job performance requirements from the NFPA standards and cross-references those requirements to the chapters within the manual. These chapters ...