Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...
At the end of 2020, Neutrik released a re-designed version of the original PowerCON which is capable of connecting/disconnecting under load when mated with the corresponding connectors, allowing a claim of compliance with IEC EN 60320-1. Cable connectors with breaking capacity are recognizable due to the '-1' in their article number like NAC3FCA-1.
A laser wire stripper is a computer-controlled machine, much like a CNC router, which uses a laser to burn off the insulation of the wire. Laser wire stripping machines are used mostly for very fine gauge wires since they do not damage the conductor.
Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75, and 90 °C, often with an ambient air temperature of 30 °C. In the United States , 105 °C is allowed with ambient of 40 °C, for larger power cables, especially those operating at more than 2 kV.
The service factor is typically in the 1.15-1.4 range, with the figure being lower for higher-power motors. For every hour of operation at the service-factor-adjusted power rating, a motor loses two to three hours of life at nominal power, i.e. its service life is reduced to less than half for continued operation at this level.
For example, if the imbalance is limited to 25% of the total load (half of one half) rather than the absolute worst-case 50%, then conductors 3/8 of the single-phase size will guarantee the same maximum voltage drop, totalling 9/8 of one single-phase conductor, 56% of the copper of the two single-phase conductors.
Sometimes 4 mm 2 cable is used if very long cable runs (to help reduce voltage drop) or derating factors such as very thick thermal insulation are involved. 1.5 mm 2 mineral-insulated copper-clad cable (known as pyro) may also be used (as mineral insulated cable can withstand heat more effectively than normal PVC) though more care must be taken ...
A cable box sits on the roadside in front of a house. A cable box is a metal enclosure (found in the vicinity of a house that has cable service) that connects a house or building to the cable provider. [1] The box is usually located near the connection points for other service connections (electric or telephone).