Reference electrodes generally used are hydrogen electrodes, calomel electrodes, and silver chloride electrodes. The indicator electrode forms an electrochemical half-cell with the interested ions in the test solution. The reference electrode forms the other half-cell. The overall electric potential is calculated as
Potentiometry passively measures the potential of a solution between two electrodes, affecting the solution very little in the process. One electrode is called the reference electrode and has a constant potential, while the other one is an indicator electrode whose potential changes with the sample's composition. Therefore, the difference in ...
A platinum wire electrode is immersed in a saturated aqueous solution of quinhydrone, in which there is the following equilibrium C 6 H 6 O 2 ⇌ C 6 H 4 O 2 + 2H + +2e −. The potential difference between the platinum electrode and a reference electrode is dependent on the activity, +, of hydrogen ions in the solution.
The pH meter measures the difference in electrical potential between a pH electrode and a reference electrode, and so the pH meter is sometimes referred to as a "potentiometric pH meter". The difference in electrical potential relates to the acidity or pH of the solution. [ 3 ]
An ion-selective electrode (ISE), also known as a specific ion electrode (SIE), is a simple membrane-based potentiometric device which measures the activity of ions in solution. [1] It is a transducer (or sensor ) that converts the change in the concentration of a specific ion dissolved in a solution into an electrical potential .
Most electrodes work over a limited range of conditions, such as pH or temperature, outside of this range the electrodes behavior becomes unpredictable. The advantage of a pseudo-reference electrode is that the resulting variation is factored into the system allowing researchers to accurately study systems over a wide range of conditions.
By Leah Douglas and Julie Steenhuysen (Reuters) -California's public health department reported a possible case of bird flu in a child with mild respiratory symptoms on Tuesday, but said there was ...
depending on whether the electrode is calibrated in millivolts or pH. For convenience the concentration, [H + ], is used in place of activity. In a titration of strong acid with strong alkali, the analytical concentration of the hydrogen ion is obtained from the initial concentration of acid, C i and the amount of alkali added during titration.