Reference electrodes generally used are hydrogen electrodes, calomel electrodes, and silver chloride electrodes. The indicator electrode forms an electrochemical half-cell with the interested ions in the test solution. The reference electrode forms the other half-cell. The overall electric potential is calculated as
Potentiometry passively measures the potential of a solution between two electrodes, affecting the solution very little in the process. One electrode is called the reference electrode and has a constant potential, while the other one is an indicator electrode whose potential changes with the sample's composition. Therefore, the difference in ...
An ion-selective electrode (ISE), also known as a specific ion electrode (SIE), is a simple membrane-based potentiometric device which measures the activity of ions in solution. [1] It is a transducer (or sensor ) that converts the change in the concentration of a specific ion dissolved in a solution into an electrical potential .
Total ionic strength adjustment buffer (TISAB) is a buffer solution which increases the ionic strength of a solution to a relatively high level. This is important for potentiometric measurements, including ion selective electrodes , because they measure the activity of the analyte rather than its concentration.
The Gran plot is based on the Nernst equation which can be written as = + {+} where E is a measured electrode potential, E 0 is a standard electrode potential, s is the slope, ideally equal to RT/nF, and {H +} is the activity of the hydrogen ion.
When a glass electrode is used to obtain the measurements on which the calculated equilibrium constants depend, the precision of the calculated parameters is limited by secondary effects such as variation of liquid junction potentials in the electrode. In practice it is virtually impossible to obtain a precision for log β better than ±0.001.
A potentiometer being calibrated and then measuring an unknown voltage. R 1 is the resistance of the entire resistance wire. The arrow head represents the moving wiper.. In this circuit, the ends of a uniform resistance wire R 1 are connected to a regulated DC supply V S for use as a voltage divider.
A platinum wire electrode is immersed in a saturated aqueous solution of quinhydrone, in which there is the following equilibrium C 6 H 6 O 2 ⇌ C 6 H 4 O 2 + 2H + +2e −. The potential difference between the platinum electrode and a reference electrode is dependent on the activity, +, of hydrogen ions in the solution.