enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Span (engineering) - Wikipedia

    en.wikipedia.org/wiki/Span_(engineering)

    In engineering, span is the distance between two adjacent structural supports (e.g., two piers) of a structural member (e.g., a beam). Span is measured in the horizontal direction either between the faces of the supports (clear span) or between the centers of the bearing surfaces (effective span): [1] A span can be closed by a solid beam or by ...

  3. Four-point flexural test - Wikipedia

    en.wikipedia.org/wiki/Four-point_flexural_test

    The major difference being that with the addition of a fourth bearing the portion of the beam between the two loading points is put under maximum stress, as opposed to only the material right under the central bearing in the case of three-point bending.

  4. Cellular beam - Wikipedia

    en.wikipedia.org/wiki/Cellular_beam

    The difference between cellular beam and castellated beam is the visual characteristic. [3] A cellular beam has round openings (circular pattern) while the castellated beam has hexagonal openings (hexagonal pattern), both of which are achieved by a cutting and welding process. [4] Cellular beams are usually made of structural steel, but can ...

  5. Deflection (engineering) - Wikipedia

    en.wikipedia.org/wiki/Deflection_(engineering)

    The deflection at any point, , along the span of a center loaded simply supported beam can be calculated using: [1] = for The special case of elastic deflection at the midpoint C of a beam, loaded at its center, supported by two simple supports is then given by: [ 1 ] δ C = F L 3 48 E I {\displaystyle \delta _{C}={\frac {FL^{3}}{48EI}}} where

  6. I-beam - Wikipedia

    en.wikipedia.org/wiki/I-beam

    The dimension of a wide-flange I-beam. In the United States, steel I-beams are commonly specified using the depth and weight of the beam. For example, a "W10x22" beam is approximately 10 in (254 mm) in depth with a nominal height of the I-beam from the outer face of one flange to the outer face of the other flange, and weighs 22 lb/ft (33 kg/m).

  7. Structural steel - Wikipedia

    en.wikipedia.org/wiki/Structural_steel

    The austenizing temperature, the temperature where a steel transforms to an austenite crystal structure, for steel starts at 900 °C (1,650 °F) for pure iron, then, as more carbon is added, the temperature falls to a minimum 724 °C (1,335 °F) for eutectic steel (steel with only .83% by weight of carbon in it).

  8. Open web steel joist - Wikipedia

    en.wikipedia.org/wiki/Open_web_steel_joist

    The LH- and DLH-Series have been designed for the purpose of extending the use of joists to spans and loads in excess of those covered by Open Web Steel Joists, K-Series. LH-Series Joists have been standardized in depths from 18 inches (460 mm) through 48 inches (1,200 mm), for spans through 96 feet (29,000 mm).

  9. Flexural strength - Wikipedia

    en.wikipedia.org/wiki/Flexural_strength

    L is the length of the support (outer) span; b is width; d is thickness; For the 4 pt bend setup, if the loading span is 1/2 of the support span (i.e. L i = 1/2 L in Fig. 4): = If the loading span is neither 1/3 nor 1/2 the support span for the 4 pt bend setup (Fig. 4): Fig. 4 - Beam under 4 point bending