Search results
Results from the WOW.Com Content Network
Kettle reboilers (Image 1) are very simple and reliable. they are similar to shell and tube type heat exchangers. They may require pumping of the column bottoms liquid into the kettle, or there may be sufficient liquid head to deliver the liquid into the reboiler. In this reboiler type, steam flows through the tube bundle and exits as condensate.
Boiler design is the process of designing boilers used for various purposes. The main function of a boiler is to heat water to generate steam. Steam produced in a boiler can be used for a variety of purposes including space heating, sterilisation, drying, humidification and power generation. The temperature or condition of steam required for ...
Assume heat transfer [2] is occurring in a heat exchanger along an axis z, from generic coordinate A to B, between two fluids, identified as 1 and 2, whose temperatures along z are T 1 (z) and T 2 (z). The local exchanged heat flux at z is proportional to the temperature difference:
A letter designation is used for the front head type, shell type, and rear head type of an exchanger. For example, a fixed tubesheet exchanger with bolted removable bonnets is designated as a 'BEM' type. A kettle type reboiler with a removable U-tube bundle is a 'BKU' type. Many different letter combinations are possible.
Typical kettle reboiler used for industrial distillation towers Typical water-cooled surface condenser. In addition to heating up or cooling down fluids in just a single phase, heat exchangers can be used either to heat a liquid to evaporate (or boil) it or used as condensers to cool a vapor and condense it to a liquid.
If the piping of a thermosiphon resists flow, or excessive heat is applied, the liquid may boil. Since the gas is more buoyant than the liquid, the convective pressure is greater. This is a well known invention called a reboiler. A group of reboilers attached to a pair of plena is called a calandria. In some circumstances, for example the ...
The precise design and specification of tubes in shell and tube heat exchangers underscore the complexities of thermal engineering. Each design aspect, from material selection to tube arrangement and fluid flow , plays a vital role in the exchanger's performance, showcasing the intricacies and precision required in this field.
Fractionation at total reflux. The Fenske equation in continuous fractional distillation is an equation used for calculating the minimum number of theoretical plates required for the separation of a binary feed stream by a fractionation column that is being operated at total reflux (i.e., which means that no overhead product distillate is being withdrawn from the column).