enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  3. IDC (electrical connector) - Wikipedia

    en.wikipedia.org/wiki/IDC_(electrical_connector)

    Pin 1 is typically indicated on the body of the connector by a red or raised "V" mark. The corresponding wire in a ribbon cable is usually indicated by red coloration, a raised molded ridge, or markings printed onto the cable insulation. On the connector pin 2 is opposite pin 1, pin 3 is next to pin 1 along the length of the connector, and so on.

  4. Mineral-insulated copper-clad cable - Wikipedia

    en.wikipedia.org/wiki/Mineral-insulated_copper...

    PVC-sheathed MICC cable. Conductor cross section area is 1.5 mm 2; overall diameter is 7.2 mm. Mineral-insulated cables at a panel board. Mineral-insulated copper-clad cable is a variety of electrical cable made from copper conductors inside a copper sheath, insulated by inorganic magnesium oxide powder.

  5. Prospective short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Prospective_short-circuit...

    The short-circuit current available on the electrical outlets is often tested when inspecting new electrical installations to make sure that the short-circuit current is within reasonable limits. A high short-circuit current on the outlet also shows that the resistance from the electrical panel to the outlet is low, so there won't be an ...

  6. ISO/IEC 11801 - Wikipedia

    en.wikipedia.org/wiki/ISO/IEC_11801

    The standard defines several link/channel classes and cabling categories of twisted-pair copper interconnects, which differ in the maximum frequency for which a certain channel performance is required: Class A: Up to 100 kHz using Category 1 cable and connectors; Class B: Up to 1 MHz using Category 2 cable and connectors

  7. Busbar - Wikipedia

    en.wikipedia.org/wiki/Busbar

    The busbar's material composition and cross-sectional size determine the maximum current it can safely carry. Busbars can have a cross-sectional area of as little as 10 square millimetres (0.016 sq in), but electrical substations may use metal tubes 50 millimetres (2.0 in) in diameter or more as busbars.

  8. Current limiting - Wikipedia

    en.wikipedia.org/wiki/Current_limiting

    Current limiting is the practice of imposing a limit on the current that may be delivered to a load to protect the circuit generating or transmitting the current from harmful effects due to a short-circuit or overload. The term "current limiting" is also used to define a type of overcurrent protective device.

  9. Ampacity - Wikipedia

    en.wikipedia.org/wiki/Ampacity

    Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75, and 90 °C, often with an ambient air temperature of 30 °C. In the United States , 105 °C is allowed with ambient of 40 °C, for larger power cables, especially those operating at more than 2 kV.