Search results
Results from the WOW.Com Content Network
0.1 × ( 12 ÷ 8 ) = 0.15 grain per dscf when corrected to a gas having a specified reference CO 2 content of 12 volume %. Notes: Although ppmv and grains per dscf have been used in the above examples, concentrations such as ppbv (i.e., parts per billion by volume), volume percent, grams per dscm and many others may also be used.
As an example, a measured NO x concentration of 45 ppmv in a dry gas having 5 volume % O 2 is: 45 × ( 20.9 - 3 ) ÷ ( 20.9 - 5 ) = 50.7 ppmv of NO x. when corrected to a dry gas having a specified reference O 2 content of 3 volume %. Note: The measured gas concentration C m must first be corrected to a dry basis before using the above equation.
In fractions like "2 nanometers per meter" (2 n m / m = 2 nano = 2×10 −9 = 2 ppb = 2 × 0.000 000 001), so the quotients are pure-number coefficients with positive values less than or equal to 1. When parts-per notations, including the percent symbol (%), are used in regular prose (as opposed to mathematical expressions), they are still pure ...
The examples don't seem to be too accurate. A drop is usually defined as 0.05 ml, which then gives;. 1 drop in 50 ml = 1‰, 50ml is a very small cup 1 drop in 50 l = 1ppm 50 l is about 11 gallons, not 40 1 drop in 50 cubic metres = 1 ppb 1 drop = 1ppt, a 50 m swimming pool is 50*25*2 = 2,500 m^3 1 drop in 50,000,000 cubic metres = 1ppq, 50,000,000 m^3 is equivalent to a lake covering a square ...
inhaled carbon monoxide induces unconsciousness in 2–3 breaths and death in < 3 min (12 800 ppm) [15] 10 −3: mM 0.32–32 mM: normal range of hydronium ions in stomach acid (pH 1.5–3.5) [16] 5.5 mM: upper bound for healthy blood glucose when fasting [17] 7.8 mM: upper bound for healthy blood glucose 2 hours after eating [17] 10 −2: cM 20 mM
Standard cubic centimeters per minute (SCCM) is a unit used to quantify the flow rate of a fluid. 1 SCCM is identical to 1 cm³ STP /min. Another expression of it would be Nml/min. Another expression of it would be Nml/min.
The factor–label method can convert only unit quantities for which the units are in a linear relationship intersecting at 0 (ratio scale in Stevens's typology). Most conversions fit this paradigm. An example for which it cannot be used is the conversion between the Celsius scale and the Kelvin scale (or the Fahrenheit scale). Between degrees ...
A variety of terms such as 'line-up level' and 'operating level' exist, and their meaning may vary from place to place. In an attempt bring clarity to level definitions in the context of programme transmission from one country to another, where different technical practices may apply, ITU-R Rec. BS.645 defined three reference levels: Measurement Level (ML), Alignment Level (AL) and Permitted ...