  2. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    The most common three-phase system will have three hot legs, 208 V to each other and 120 V each to the neutral. An older, but still widely used, high-leg delta system uses three phases with 240 volts phase-to-phase for motor loads, and 120 volts for lighting loads by use of a center-tapped transformer; two of the phases are 120 volts to neutral ...

  3. Mains electricity by country - Wikipedia

    en.wikipedia.org/wiki/Mains_electricity_by_country

    For example, in North America, a unique split-phase system is used to supply to most premises that works by center tapping a 240 volt transformer. This system is able to concurrently provide 240 volts and 120 volts. Consequently, this allows homeowners to wire up both 240 V and 120 V circuits as they wish (as regulated by local building codes).

  4. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    They are also found on some RVs for connecting to shore power. RVs in the US are equipped for 120 V 30 A or 240 V 50 A service, and use a cord to connect to a receptacle at the campsite, usually on a power pedestal with one or more receptacles providing 120 V 30 A (TT30R), 240 V 50 A (14-50R), or 120 V 15/20 A (5-20R) service.

  5. Mains electricity - Wikipedia

    en.wikipedia.org/wiki/Mains_electricity

    As in the UK, 240 V is within the allowable limits and "240 volt" is a synonym for mains in Australian and British English. In the United States [13] [14] and Canada, [15] national standards specify that the nominal voltage at the source should be 120 V and allow a range of 114 V to 126 V (−5% to +5%). Historically, 110 V, 115 V and 117 V ...

  6. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    So if A–B, B–C and C–A are all 240 volts, then A–N and C–N will both be 120 volts, but B–N will be 208 volts. Other types of three-phase supplies are wye connections, ungrounded delta connections, or corner-grounded delta [2] (ghost leg configuration) connections. These connections do not supply split single-phase power, and do not ...

  7. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    The phase shift in Europe is 120°, as is the case with three-phase current. That is why we calculate 130 V × √ 3 = 225 V. A three-phase final step-down transformer is then used. One house gets phases A and B, the next house gets phase B and C, the third house gets phase A and C.

  8. Sleek Socket Ultra-Thin Electrical Outlet Cover is a must-have

    www.aol.com/lifestyle/sleek-socket-amazon...

    Meanwhile, the Sleek Socket Electrical Outlet Cover has a three-foot cable itself that can be easily hidden away behind your electronics, clamped to your baseboard or stowed behind your ...

  9. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    A three-phase induction motor has a simple design, inherently high starting torque and high efficiency. Such motors are applied in industry for many applications. A three-phase motor is more compact and less costly than a single-phase motor of the same voltage class and rating, and single-phase AC motors above 10 hp (7.5 kW) are uncommon. Three ...