Search results
Results from the WOW.Com Content Network
The only terminal remaining is the source. This is a common-source FET circuit. The analogous bipolar junction transistor circuit may be viewed as a transconductance amplifier or as a voltage amplifier. (See classification of amplifiers). As a transconductance amplifier, the input voltage is seen as modulating the current going to the load.
Like a standard operational amplifier, the OTA also has a high impedance differential input stage and may be used with negative feedback. [3] But the OTA differs in that: The OTA outputs a current while a standard operational amplifier outputs a voltage. The OTA is usually used "open-loop"; without negative feedback in linear applications.
Referring to the above diagram, if the op-amp is assumed to be ideal, then the voltage at the inverting (-) input is held equal to the voltage at the non-inverting (+) input as a virtual ground. The input voltage passes a current V in / R 1 {\displaystyle V_{\text{in}}/{R_{1}}} through the resistor producing a compensating current flow through ...
Figure 2: A negative-feedback amplifier. The circuit can be explained by viewing the transistor as being under the control of negative feedback.From this viewpoint, a common-collector stage (Fig. 1) is an amplifier with full series negative feedback.
Typical instrumentation amplifier schematic. An instrumentation amplifier (sometimes shorthanded as in-amp or InAmp) is a type of differential amplifier that has been outfitted with input buffer amplifiers, which eliminate the need for input impedance matching and thus make the amplifier particularly suitable for use in measurement and test equipment.
In electronics engineering, frequency compensation is a technique used in amplifiers, and especially in amplifiers employing negative feedback.It usually has two primary goals: To avoid the unintentional creation of positive feedback, which will cause the amplifier to oscillate, and to control overshoot and ringing in the amplifier's step response.
A fully differential amplifier (FDA) is a DC-coupled high-gain electronic voltage amplifier with differential inputs and differential outputs. In its ordinary usage, the output of the FDA is controlled by two feedback paths which, because of the amplifier's high gain, almost completely determine the output voltage for any given input.
A transconductance amplifier (g m amplifier) puts out a current proportional to its input voltage. In network analysis, the transconductance amplifier is defined as a voltage controlled current source (VCCS). These amplifiers are commonly seen installed in a cascode configuration, which improves the frequency response.