Search results
Results from the WOW.Com Content Network
It is common for VAV boxes to include a form of reheat, either electric or hydronic heating coils. [4] While electric coils operate on the principle of electric resistance heating, whereby electrical energy is converted to heat via electric resistance, hydronic heating uses hot water to transfer heat from the coil to the air. The addition of ...
Diagramatic operation of a thermal wheel Ljungström Air Preheater by Swedish engineer Fredrik Ljungström (1875–1964). A thermal wheel, also known as a rotary heat exchanger, or rotary air-to-air enthalpy wheel, energy recovery wheel, or heat recovery wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of air-handling units or rooftop ...
However, variations such as CAV with reheat, CAV multizone, and CAV primary-secondary systems can serve multiple zones and larger buildings. In mid- to large-size buildings, new central CAV systems are somewhat rare. Due to fan energy savings potential, variable air volume (VAV) systems are more common. However, in small buildings and ...
The operation schedule of a space and the control strategy of the radiant system play a key role in the proper functioning of the system. Many types of radiant systems incorporate hard surfaces which influence indoor acoustics. Additional acoustic solutions may need to be considered.
DOAS air handling unit with heat recovery wheel and passive dehumidification. A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the ...
The SEER (Seasonal Energy Efficiency Ratio) rating of a unit is the cooling output during a typical cooling-season divided by the total electric energy input during the same period. The higher the unit's SEER rating the more energy efficient it is. smoke damper A damper or adjustable louver designed to augment the ventilation of a space during ...
To train as a building services engineer, the academic requirements are GCSEs (A-C) / Standard Grades (1-3) in Maths and Science, which are important in measurements, planning and theory. Employers will often want a degree in a branch of engineering, such as building environment engineering , electrical engineering or mechanical engineering.
Such a control sequence is supported by a pollutant sensor (e.g. carbon dioxide sensor), a variable frequency drive (VFD) on the fan supplying the zone, individual VAV boxes with reheat serving each space in the zone, and airflow measuring stations. [4] Research has been conducted on the application of DCV in constant-air-volume (CAV) systems.