Extinction coefficient refers to several different measures of the absorption of light in a medium: Attenuation coefficient , sometimes called "extinction coefficient" in meteorology or climatology Mass extinction coefficient , how strongly a substance absorbs light at a given wavelength, per mass density
absorption coefficient is essentially (but not quite always) synonymous with attenuation coefficient; see attenuation coefficient for details; molar absorption coefficient or molar extinction coefficient , also called molar absorptivity , is the attenuation coefficient divided by molarity (and usually multiplied by ln(10), i.e., decadic); see ...
The SI unit of molar absorption coefficient is the square metre per mole (m 2 /mol), but in practice, quantities are usually expressed in terms of M −1 ⋅cm −1 or L⋅mol −1 ⋅cm −1 (the latter two units are both equal to 0.1 m 2 /mol).
Thus a scattering coefficient μ s and an absorption coefficient μ a can be combined into a total extinction coefficient μ = μ s + μ a. [ 6 ] Importantly, Beer also seems to have conceptualized his result in terms of a given thickness' opacity, writing "If λ is the coefficient (fraction) of diminution, then this coefficient (fraction) will ...
The SI unit of mass attenuation coefficient is the square metre per kilogram (m 2 /kg). Other common units include cm 2 /g (the most common unit for X-ray mass attenuation coefficients) and L⋅g −1 ⋅cm −1 (sometimes used in solution chemistry). Mass extinction coefficient is an old term for this quantity. [1]
These two different types of hemoglobin exhibit different absorption spectra that are normally represented in terms of molar extinction coefficients, as shown in Figure 1. The molar extinction coefficient of Hb has its highest absorption peak at 420 nm and a second peak at 580 nm. Its spectrum then gradually decreases as light wavelength increases.
A. R. Forouhi and I. Bloomer deduced dispersion equations for the refractive index, n, and extinction coefficient, k, which were published in 1986 [1] and 1988. [2] The 1986 publication relates to amorphous materials, while the 1988 publication relates to crystalline.
The magnitude of the constant φ may be higher than the value of the molar extinction coefficient, ε, for a species. When this is so, the detection limit for that species will be lower. At high solute concentrations, fluorescence intensity becomes non-linear with respect to concentration due to self-absorption of the scattered radiation.