Search results
Results from the WOW.Com Content Network
The American Concrete Institute (ACI, formerly National Association of Cement Users or NACU) is a non-profit technical society and standards developing organization. ACI was founded in January 1905 during a convention in Indianapolis. [1] [2] The Institute's headquarters are currently located in Farmington Hills, Michigan, USA. ACI's mission is ...
The tension failure loads predicted by the CCD method fits experimental results over a wide range of embedment depth (e.g. 100 – 600 mm). [2] Anchor load bearing capacity provided by ACI 349 does not consider size effect, thus an underestimated value for the load-carrying capacity is obtained for large embedment depths.
In structural and mechanical engineering, the shear strength of a component is important for designing the dimensions and materials to be used for the manufacture or construction of the component (e.g. beams, plates, or bolts). In a reinforced concrete beam, the main purpose of reinforcing bar (rebar) stirrups is to increase the shear strength.
Developments in concrete continued with the construction in 1848 of a rowing boat built of ferrocement - the forerunner of modern reinforced concrete - by Joseph-Louis Lambot. He patented his system of mesh reinforcement and concrete in 1855, one year after W.B. Wilkinson also patented a similar system. [19]
The derivation of the maximum arching moment of resistance of laterally restrained concrete bridge deck slabs utilised Rankin's [21] idealised elastic-plastic stress-strain criterion for concrete, valid for concrete cylinder strengths up to at least 70N/mm 2, which he had derived on the basis of Hognestad, Hanson and McHenry's [23] ultimate ...
Lift slab construction (also called the Youtz-Slick Method) is a method of constructing concrete buildings by casting the floor or roof slab on top of the previous slab and then raising (jacking) the slab up with hydraulic jacks. This method of construction allows for a large portion of the work to be completed at ground level, negating the ...
The ACI Building Code Requirements put the following restrictions on amount of spiral reinforcement. ACI Code 7.10.4.2: For cast-in-place construction, size of spirals shall not be less than 3/8 in. diameter. ACI Code 7.10.4.3: Clear spacing between spirals shall not exceed 3 in., nor be less than 1in.
This earthquake engineering technology, which is a kind of seismic vibration control, can be applied both to a newly designed building and to seismic upgrading of existing structures. [15] [16] Normally, excavations are made around the building and the building is separated from the foundations. Steel or reinforced concrete beams replace the ...