enow.com Web Search

  1. Ad

    related to: insulation resistance test acceptable value for home health equipment

Search results

  1. Results from the WOW.Com Content Network
  2. Electrical safety testing - Wikipedia

    en.wikipedia.org/wiki/Electrical_safety_testing

    Acceptable values of insulation resistance vary depending on circuit purpose, industry, and country. Typically, standards will dictate acceptable values. An insulation resistance test can be used for simple go/no-go testing, or for periodic condition assessment, where routine insulation resistance tests are performed, with the results tracked ...

  3. Electrical isolation test - Wikipedia

    en.wikipedia.org/wiki/Electrical_isolation_test

    A minimum acceptable resistance value is usually specified (typically in the mega ohm (MΩ) range per circuit tested). Multiple circuits having a common return may be tested simultaneously, provided the minimum allowable resistance value is based on the number of circuits in parallel. Five basic isolation test configurations exist: [3]

  4. Dielectric withstand test - Wikipedia

    en.wikipedia.org/wiki/Dielectric_withstand_test

    A dielectric withstand test may be done as a factory test on new equipment, or may be done on apparatus already in service as a routine maintenance test. [2] An insulation test set; in this pattern, a hand-cranked generator provides the high voltage and the scale is directly calibrated in megohms. Voltage withstand testing is done with a high ...

  5. Megohmmeter - Wikipedia

    en.wikipedia.org/wiki/Megohmmeter

    Megohmmeter M1101M. A Megohmmeter or insulation resistance tester, is a special type of ohmmeter used to measure the electrical resistance of insulators. [1] Insulating components, for example cable jackets, must be tested for their insulation strength at the time of commissioning and as part of maintenance of high voltage electrical equipment and installations.

  6. Portable appliance testing - Wikipedia

    en.wikipedia.org/wiki/Portable_appliance_testing

    Alternatively, measured insulation resistance (IR [12]) values are not less than 1MΩ for Class I and Class II appliances at 500 V d.c., or at 250 V d.c. [13] to avoid the equipment apparently failing the test because the metal oxide varistors (MOVs) or electro-magnetic interference (EMI) suppression triggered, for equipment containing voltage ...

  7. IEC 61010 - Wikipedia

    en.wikipedia.org/wiki/IEC_61010

    Part 2-034: Particular requirements for measurement equipment for insulation resistance and test equipment for electric strength; Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials

  8. Cable fault location - Wikipedia

    en.wikipedia.org/wiki/Cable_fault_location

    The insulation of the cable plays a significant role in this. While paper-impregnated cables are particularly susceptible to external chemical and thermal influences, in high-voltage PE or XLPE cables the polyethylene insulation of the conductor is affected, leading to partial breakdowns and cracks that “eat away” the insulation.

  9. ASHRAE 55 - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_55

    In general, body motion decreases the clothing insulation by pumping air through clothing. ANSI/ASHRAE Standard 55 recognizes that this effect varies largely depending on the nature of the movements and the nature clothing, such as how tight the clothing is. Thus, it only provides an approximation of the clothing insulation value of a moving ...

  1. Ad

    related to: insulation resistance test acceptable value for home health equipment