enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. ASHRAE 90.1 - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_90.1

    ANSI/ASHRAE/IES Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings is an American National Standards Institute (ANSI) standard published by ASHRAE and jointly sponsored by the Illuminating Engineering Society (IES) that provides minimum requirements for energy efficient designs for buildings except for low-rise residential buildings (i.e. single-family homes ...

  3. United States building energy codes - Wikipedia

    en.wikipedia.org/wiki/United_States_building...

    ASHRAE 90.1 follows a similar path of development and revision. [6] Though ASHRAE 90.1 is revised and published every three years just like the IECC, people can submit interim revisions at any time within this period. [5] ASHRAE has a standards committee that manages the process, and votes on the final versions of the energy code. [5]

  4. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The respective tables of data were generally developed by using the more complex transfer function method to determine the various cooling loads for different types of heating. [ 2 ] [ 3 ] The results gained by doing so are then normalized for each type of heat gain used for the tables, CLTD, CLF, and SCL.

  5. Ductwork airtightness - Wikipedia

    en.wikipedia.org/wiki/Ductwork_airtightness

    There are two major systems to classify ductwork airtightness, one based on European standards, the other based on ASHRAE standard 90.1-2010.Both are based on the leakage airflow rate at a given ductwork pressure divided by the product of the ductwork surface area and the same ductwork pressure raised to the power 0.65.

  6. ASHRAE - Wikipedia

    en.wikipedia.org/wiki/ASHRAE

    ASHRAE was founded in 1894 at a meeting of engineers in New York City, formerly headquartered at 345 East 47th Street, and has held an annual meeting since 1895. [4] Until 1954 it was known as the American Society of Heating and Ventilating Engineers (ASHVE); in that year it changed its name to the American Society of Heating and Air-Conditioning Engineers (ASHAE). [5]

  7. ASHRAE Handbook - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_Handbook

    Members of ASHRAE receive the current volume, in both print and CD-ROM form, each year as a basic membership benefit. An enhanced electronic version, known as ASHRAE Handbook Online is a web-based version updated annually that contains the four latest volumes as well as extra content such as calculations, demonstration videos, and spreadsheets ...

  8. Lighting power density - Wikipedia

    en.wikipedia.org/wiki/Lighting_power_density

    Space By Space Method. A defined list of many possible space types within a building the associated watts per square foot allowance. For example, ANSI/ASHRAE/IESNA Standard 90.1-2007 allows the Emergency Space of a hospital to be designed for 2.7 watts per square foot, but the Recovery areas of a hospital would be allowed 0.8 watts per square foot.

  9. R-value (insulation) - Wikipedia

    en.wikipedia.org/wiki/R-value_(insulation)

    With an area of 100 m 2, the heat energy being lost is 0.25 W/(K⋅m 2) × 18 °C × 100 m 2 = 450 W. There will be other losses through the floor, windows, ventilation slots, etc. But for that material alone, 450 W is going out, and can be replaced with a 450 W heater inside, to maintain the inside temperature.