    related to: what temperature is a fire alarm required db

Search results

  1. Results from the WOW.Com Content Network
  2. Fire alarm notification appliance - Wikipedia

    en.wikipedia.org/wiki/Fire_alarm_notification...

    95 dB @ 3,100 Hz tone are used in many current notification devices. [1] 80 dB @ 520 Hz tone are used in newer notification devices. [1] 70 dB to 100 dB weighted for human hearing (higher decibels, in the 100 to 115 dB range, were common with older electromechanical horns) [citation needed] Light (visible signals) 15 cd to 1,000 cd candela ...

  3. Smoke detector - Wikipedia

    en.wikipedia.org/wiki/Smoke_detector

    The Life Safety Code (NFPA 101), passed by the US National Fire Protection Association (NFPA) in 1976, first required smoke alarms in homes. [10] Smoke alarm sensitivity requirements in UL 217 were modified in 1985 to reduce susceptibility to nuisance alarms. [10]

  4. Fire alarm system - Wikipedia

    en.wikipedia.org/wiki/Fire_alarm_system

    A fire alarm system is a building system designed to detect, alert occupants, and alert emergency forces of the presence of fire, smoke, carbon monoxide, or other fire-related emergencies. Fire alarm systems are required in most commercial buildings.

  5. Heat detector - Wikipedia

    en.wikipedia.org/wiki/Heat_detector

    A heat detector is a fire alarm device designed to respond when the convected thermal energy of a fire increases the temperature of a heat sensitive element. The thermal mass and conductivity of the element regulate the rate flow of heat into the element.

  6. EN 54 - Wikipedia

    en.wikipedia.org/wiki/EN_54

    The EN 54 series of standards covers the following topics and product groups related to fire detection and fire alarm systems: [6] [7] Introduction: the introduction to the series of standards contains a diagram of a fire alarm system as well as numerous definitions of terms that are used in the other parts of the series of standards.

  7. NFPA 72 - Wikipedia

    en.wikipedia.org/wiki/NFPA_72

    The NFPA 72 (National Fire Alarm and Signaling Code) is a standard published by the National Fire Protection Association every 3 years for installation of fire alarm systems and emergency communication systems in the United States.

  8. Minimum detectable signal - Wikipedia

    en.wikipedia.org/wiki/Minimum_detectable_signal

    This required difference in power levels of the signal and the noise floor is known as the signal-to-noise ratio (SNR). To establish the minimum detectable signal (MDS) of a receiver we require several factors to be known. Required signal-to-noise ratio (SNR) Detection bandwidth (BW) Temperature T 0 of the receiver system; Receiver noise figure ...

  9. Linear heat detection - Wikipedia

    en.wikipedia.org/wiki/Linear_Heat_Detection

    Linear heat detection (LHD) cable is essentially a two-core cable terminated by an end-of-line resistor (resistance varies with application). The two cores are separated by a polymer plastic, that is designed to melt at a specific temperature (commonly 68 °C for building applications [1]), and without which causes the two cores to short.