An ST elevation is considered significant if the vertical distance inside the ECG trace and the baseline at a point 0.04 seconds after the J-point is at least 0.1 mV (usually representing 1 mm or 1 small square) in a limb lead or 0.2 mV (2 mm or 2 small squares) in a precordial lead. [2]
ST deviation ≥1 mm (0.1 mV) discordant with QRS polarity, in any lead with max (R|S) voltage ≤6 mm (0.6 mV). The BARCELONA algorithm attained the highest sensitivity (95%), significantly higher ( P <0.01) than Sgarbossa and Modified Sgarbossa rules, as well as the highest negative predictive value (97%), while maintaining 89% specificity .
In electrocardiography, the ST segment connects the QRS complex and the T wave and has a duration of 0.005 to 0.150 sec (5 to 150 ms). It starts at the J point (junction between the QRS complex and ST segment) and ends at the beginning of the T wave.
The J-point is easy to identify when the ST segment is horizontal and forms a sharp angle with the last part of the QRS complex. However, when the ST segment is sloped or the QRS complex is wide, the two features do not form a sharp angle and the location of the J-point is less clear.
A right bundle branch block typically causes prolongation of the last part of the QRS complex and may shift the heart's electrical axis slightly to the right. The ECG will show a terminal R wave in lead V1 and a slurred S wave in lead I. Left bundle branch block widens the entire QRS, and in most cases shifts the heart's electrical axis to the ...
The ST-segment is upsloping and there is also often ST-segment elevation of 0.5 to 2 mm in lead aVR. [1] [2] The QRS complex is either normal or slightly wide. [1] Treatment is as per an ST elevation MI (STEMI), with primary percutaneous coronary intervention (PCI) being preferred.
When an individual is in normal sinus rhythm, the ECG characteristics of WPW are a short PR interval (less than 120 milliseconds in duration), widened QRS complex (greater than 120 milliseconds in duration) with slurred upstroke of the QRS complex, and secondary repolarization changes (reflected in ST segment-T wave changes). [citation needed]
ST elevation ≥1 mm in a lead with a positive QRS complex (i.e.: concordance) - 5 points; concordant ST depression ≥1 mm in lead V1, V2, or V3 - 3 points; ST elevation ≥5 mm in a lead with a negative (discordant) QRS complex - 2 points; ≥3 points = 90% specificity of STEMI (sensitivity of 36%) [2]